离岸价格
Get Latest Price|
- Minimum Order
国:
China
モデル番号:
-
离岸价格:
ロケーション:
china
最低注文量の価格:
-
最低注文量:
-
パッケージの詳細:
-
納期:
-
供給能力:
-
支払いタイプ:
-
製品グループ :
-
連絡先担当者 Ms. Annie
Suzhou, Jiangsu
TECHNIQUES SPECIFICATIONS
Physical specifications
Screen: *0.4 '' LCD Display Screen
Suitable Adult & Child
Mode: pneumatically powered and electrically
controlled system
Working Mode: Closed; Semi-Closed; Semi-Open
Circuit Breathing circuit integrated
standards
Flowmeters: 5 Tubes Flowmeters:
O2:0.1~*0L/Min, N2O:0.1~*0L/Min; Air: 0.1~*0L / Min
Trolley: Fitted with 4 nos anti-static rubber castors; two of which
are lockable for braking and easy maneuverability with foot
operated brake provisions
Drawer unit TWO drawers totally
extractable
Technical Specifications:
Gas requirement: Medical oxygen and nitrous oxide with a pressure
ranging from O2: 0.*2~0.6MPa ; NO2: 0.*2 MPa to 0.6 MPa.
safety valve <*2.5 kPa
Respiratory Rate 1~*9bpm
oxygen concentration in the mixed gas N2O/O2 > *1%
Oxygen Flush: *5~*5 L/min
modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV,
PCV, VCV, PEEP, MANUAL, SIGH
PEEP: 0 ~ 2.0 kPa
Inspiratory trigger pressure *1.0kPa ~ 2.0
kPa
IMV frequency: ..
I/E Ratio: 8:1 ~ 1:*0, Has the inverse ratio
ventilation
Tidal Volume 0 ~ ***0 ML
Inspiratory Plateau: 0~1s
O2 Concentration: *1%~**0%
Sigh: one deep breath per *0 ~ **0 controlled respirations, the
inspiration time is 1.5 times of the setting point
Maximum safety pressure: <= *2.5 kPa
Pressure limit range: 0 ~ 6.0 kPa
Airway pressure alarm: Audible and visual and with yellow and red
color indicating Lower: 0.2kPa~5.0kPa;
Upper: 0.3~6.0 kPa
±0.2 kPa
Tidal volume alarm: Audible and visual and with yellow and red
color indicating upper alarm: *0 to ***0ml, lower
alarm: 0~***0ml
Oxygen concentration alarm: Audible and visual and with yellow and
red color indicating upper alarm: *1% ~**0%;
lower alarm:*0%~*0%
Power Supply Alarm "Ac/dc power supply are after
failing to send out alarm immediately
Alarm Time: keep >**0s"
The airway pressure continues to be higher than *5 hPa?±1 hPa for
*5s±1s, then the machine will raise an audible alarm, the pressure
will be displayed in red and the continuous high pressure red alarm
wording is displayed on the screen of the anesthetic
respirator.
Operating conditions
Ambient temperature: *0 ~ *0oC
Relative humidity: no higher than *0 %
Atmospheric pressure: **0 hPa ~ ***0 hPa
Power requirement: ******0 Vac, *0/*0 Hz;
Attention: the AC power supply used for the anesthesia machine must
be well grounded.
Attention: the anesthesia machine used must be equipped with a
carbon dioxide monitor complying with ISO ***8:***3, an oxygen
monitor complying with ISO ***7:***7 and an expiratory gas volume
monitor complying with *1.**1.4.2 of Medical Electrical Equipment
Part II: Special Requirements for Safety and Basic Performance of
Anesthesia System.
Storage
Ambient temperature: **5oC?~ **0oC
Relative humidity: no higher than *5 %
Atmospheric pressure: *6 kPa ~ **6 kPa.
It should be stored in a room without corrosive gas and well
ventilated
Package
packaging box comply with the requirement of GB/T
****4
Between the packaging box and product, soft material with
appropriate thickness provided to prevent loosening and mutual
friction during transportation
Moisture protection and rain protection to ensure that product is
protected from natural damage.
Safty & Alarm
Oxygen Alarm It alarms when the oxygen
supply from pipe or cylinders lower than 0.2MPa
Ventilation Volume Alarm Lower: 0~*2L/Min;
Up: *8L/ Min
Power Alarm It Alrmas while AC and DC supply
failure ; Keep alraming time: >**0s
Air Tract Pressure Alarm Lower: 0.2kPa ~5.0 kPa;
Up: 0.3kPa ~ 6.0kPa
国: | China |
モデル番号: | - |
离岸价格: | Get Latest Price |
ロケーション: | china |
最低注文量の価格: | - |
最低注文量: | - |
パッケージの詳細: | - |
納期: | - |
供給能力: | - |
支払いタイプ: | - |
製品グループ : | - |