あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。
今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
ALuminum Conductor Steel Reinforced ACSR Bare Conductor
Next

ALuminum Conductor Steel Reinforced ACSR Bare Conductor

离岸价格

Get Latest Price

0.1 ~ 1 / Kilometer ( Negotiable )

|

50 Kilometer Minimum Order

国:

China

モデル番号:

-

离岸价格:

0.1 ~ 1 / Kilometer ( Negotiable ) Get Latest Price

ロケーション:

-

最低注文量の価格:

0.1 per Kilometer

最低注文量:

50 Kilometer

パッケージの詳細:

wooden drum;wooden_iron drum;iron drum.

納期:

sample(3d);in stock(10d);general cargo(15d);OEM/OD

供給能力:

10000 Kilometer per Week

支払いタイプ:

-

製品グループ :

今すぐお問い合わせください
無料会員

連絡先担当者 Mary

Zhengzhou, Henan

今すぐお問い合わせください

タイトルまたは説明

ALuminum Conductor Steel Reinforced ACSR Bare Conductor
 Applications

ACSR is a composite conductor consisting of seven or more aluminium and galvanized steel wires built up in concentric-lay-stranded layers. 

Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR provides optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. 

Advantage

 a. Excellent electric and mechanical characteristics

 b.Good conductivity,Resistance chemical corrosion and heat-ageing, environment stress

 c.Unit volume light, Simple in structure

 d. Convenient to use, especially for laying across

Construction 

Aluminum alloy ****-H**9 wires, concentrically stranded about a steel core.

Core wire for ACSR is available with class A, B, or C galvanizing(GA,GB,GC); aluminized,aluminum wrapped, aluminum coated Or aluminum-clad (AW). The steel core may be single wire or stranded wires depending on the size.

Additional corrosion protection is available through the application of grease to the core

or infusion of the complete cable with grease. 

Material Standard 
(1).The hard aluminum conductor used for AAC and ACSR conforms to the standard GB/T *********7(equivalent to IEC ****9: ***7). 
(2).The zinc coated steel wire used for ACSR conforms to IEC ****8: ***7. 
(3).Production can be arranged according to customers requirements for material standard, etc. 

Specifications 
ACSR bare conductor meets or exceeds the following ASTM specifications

B***0 Aluminum Wire, ****-H*9 for Electrical Purposes 
B***1 Aluminum Conductors, Concentric-Lay-Stranded 
B***2 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) 
B***1 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AW) 
B***8 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/GA
,GB,GC) 
B***0 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR/AZ) 

B**2, B**3 rear earth aluminum conductor steel reinforced

(ACSR/RE: ACSR/MA, MB, MC, MS)

 

 Other manufacturing standardsGB/T ********8, IEC ****9, EN ****2, DIN ****4, BS **5 , ASTM B**2, NFC *****0

 

We factory also supply below bare conductor:

(1) all aluminum conductor (AAC)
(2) all aluminum alloy conductor(AAAC)
(3) anti-corrosion type ACSR
(4) aluminum conductor aluminum clad steel reinforced(ACSR/AW)
(5)rear earth aluminum conductor steel reinforced(ACSR/RE)
(6)aluminum conductor aluminum alloy reinforced(ACAR)
(7)aluminum alloy conductor steel reinforced(AACSR)
(8)all steel conductor
(9)aluminum coated steel conductor
 

Relevant Standard:

All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS **8 (Part-I, II, IV), IEC***8
(AAAC) Conductor as per ASTM-B********2
(AAAC) Conductor as per BS*********0
(AAAC) Conductor IS: ***-IV****4
(ACSR) as per ASTM-B********2
(AAC) as per BS**********0
(AAC) as per IS*****1: ***6
(AAC) as per ASTM-B********0
(ACSR) as per IS: ***-II: ***6 & IS: ***-V: ***2
(ACSR) BS****-II****0
(AACSR) as per IEC*********1

 

 

 

Property of ACSR Bear Conductor:

  • Ambient Temperature - *0°C
  • Maximum Conductor Temperature - *5°C
  • Wind Speed - 0,*4 m/s
  • Normal Stringing Temperature  *5°C
  • Solar Radiation - 0,**9 Wcm*2
  • Solar Absorption Coefficient - 1

Sag and Tension charts are available on request. The following information to be supplied:

 

(a) Span length

(b) Maximum design load (*5% of UTS if not specified)

(c) Stringing temperature.

 

 

Notes 

Resistance is calculated using ASTM standard increments of stranding and metal conductivity of *1.2% IACS for EC (***0) and 8% IACS for steel. AC (*0Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. 
Current ratings are based on *5oC conductor temperature, *5oC ambient, 2ft/s wind, *6/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.

国: China
モデル番号: -
离岸价格: 0.1 ~ 1 / Kilometer ( Negotiable ) Get Latest Price
ロケーション: -
最低注文量の価格: 0.1 per Kilometer
最低注文量: 50 Kilometer
パッケージの詳細: wooden drum;wooden_iron drum;iron drum.
納期: sample(3d);in stock(10d);general cargo(15d);OEM/OD
供給能力: 10000 Kilometer per Week
支払いタイプ: -
製品グループ : Overhead bare conductor

Send a direct inquiry to this supplier

To:

Mary < Zhengzhou Zhengcable Group Co., Ltd. >

私は知りたい: