Scope of Application
DZ*7LE**3 Residual Current Circuit Breaker
(rccb) is used for the line of AC *0Hz, rated voltage of **0V,
rated current of *0A, as leakage and overload protection for home
and similar purposes, to prevent the fire or the personnel casualty
caused by circuit leakage or electric shock, also to provide
over-voltage protection for excessively rised voltage caused by the
grid fault.
This ELCB breaker complies with standards of
IEC******1: ***6, GB****7.1 "Residual current operated
circuit-breakers with overcurrent protection for household and
similar purposes (RCBO) Part 1: General rules" and other
standards.
Normal operating conditions and installation
conditions
â– Altitude is not more than ***0
meters;
â– Ambient air temperature:
*5℃~*0℃, and average temperature in *4h below
**5℃;
â– The location of the air relative
humidity in the highest temperature + *0℃ for not more than *0%;
For example, + *0℃ for *0% . And consider the temperature changes
in product on the surface of the gel;
â– Installation conditions: installed
in the place without impact vibration and invasion of rain and
snow; no explosion hazard in the medium, and medium without enough
to corrode the metal and destruction of gas and electric insulation
dust;
â– Pollution degree:
2;
â– Installation category:
â…¢;
â– Electromagnetic environment is
Environment B;
â– The external magnetic field of
installation site in any direction should not exceed 5 times of the
geomagnetic field;
â– TH***7.5 rail installation,
installed in the distribution box, power distribution cabinet or
box;
â– The installation adopts vertical
installation, The inclination of the mounting plane to the vertical
plane should not exceed ± 5 °, handle-up means
power-on.
Normal operating conditions and installation
conditions
â– Rated current:
6,*0,*6,*0,*5,*2,*0,*0,*3 A
â– Rated working voltage: **0 / **0V
AC
â– Rated insulation voltage:
**0V
â– Rated residual operating current:
*0,*0,*5,**0,**0 mA
â– Trip indicator: DZ*7LE residual
current action on the trip instructions, the reset pops up
for the leakage trip
â– Manual control: The handle allows
two reset modes
â–¡ Overcurrent fault: The
circuit breaker and the residual current operating device are
simultaneously reset
â–¡ Leakage fault: the residual
current action device first reset, after the circuit breaker
reset
â– Mechanical life: *0,**0
times
â– Electrical life: ***0
times
â– Wiring
â–¡ 6 ~ *2A, can be connected to
*6mm ² and the following wires
â–¡ *0 ~ *0A, can be connected
to *5mm ² and below the wire
â– Meet the standard: IEC******1 /
GB****7.1
â– Compliance with certification: CCC
certification
â– Tripping
characteristics
â–¡ C-shaped
curve
Protects conventional loads and distribution
cables
Tripping characteristics: instantaneous trip
range (5 ~ *0) In
â–¡ D-shaped
curve
Protection of the starting current of the
impact of large load (such as transformers, etc.)
Tripping characteristics: instantaneous trip
range (*0 ~ *4)
国: | China |