Extra-corporeal shock wave
Next

Extra-corporeal shock wave

离岸价格

Get Latest Price

10 ~ 30 / ( Negotiable )

|

1 Set Minimum Order

国:

China

モデル番号:

HD.ESWL-V

离岸价格:

10 ~ 30 / ( Negotiable ) Get Latest Price

ロケーション:

china

最低注文量の価格:

10

最低注文量:

1 Set

パッケージの詳細:

wooden

納期:

30 days

供給能力:

500 Set per Month

支払いタイプ:

T/T

製品グループ :

-

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Doris

qingshuihe, Shenzhen, Guangdong

今すぐお問い合わせください

製品仕様

  • PLC control :15" SONY LCD
  • 9" intensifier:1000 thousand pixel CCD

タイトルまたは説明

Both C arm and X-ray located. Directly, exactly and conveniently locating, or equip with B- ultrasound device, and it will both B-ultrasound and X-ray locating.
    The mission success rate of broken calculi once can be improved because spherical motion small C arm shock wave source system could choose the best angle.
 Low energy, minimally invasive, therapy is effective, and it could compatibility with good shock wave source, more choices for clients.
 High quality X ray image system and high definition monitor, the level of image resolution ratio is upper than national standard.
 Control system could infinitely variable control shock wave energy, triggering frequency range of choice is wide, equip with talkback system, it could be control both table side and separate room.
 Sphere of activities range of shock wave source is much wider.
Caution: Main function of this equipment is use for therapy calculus, other function couldn’t compare with professional device or equipment.
Environmental temperature: *5½*5„ƒ
Relative humid: *5½*5%
Atmospheric pressure: *6½**6kPa
 Power requirements: AC 3N~**0V±*0% *0±1Hz, PW≤5kW (excluding film)
Water requirements: Dematerialized water
Main room ≥4m×4m×2.5m
Auxiliary room ≥2m×4m
X-ray proof of the main room(standard details should consult the demand of GB***6.*2)
Discharging range: EH: *2~*8kV EM: 5~*1kV
Capacity storage: EH: 5~*4J    EM: *3~**8J
Parameter of second focus of shock wave
Shock wave front ≤0.5mS
Shock wave width ≤1mS
Focus range of second focus of shock wave: radial±7mm¼axial±*2.5mm¼ˆEH¼‰
                                    radial±7.5mm¼axial±*0mm¼ˆEM¼‰
Height of second focus ≥**0mm
Shock wave generator move spherical motion round focus area
Shock wave generator is compatible both with electromagnetic and electrohydraulic.
 X-ray localization (Both C arm and X-ray located)
X-ray tube voltage: *0~**0kV
X-ray tube currency ≤5mA (only fluoroscopy)
X-ray image definition ≥*4LP/mm
High resolution intensifier and high definition CCD vidicon
B-ultrasound localization (Optional)
Axes extension of probe
The localization error may be caused by the probe makes linear movement relative to the focus is within ±2mm
 The localization error may be caused by the probe makes annular movement relative to the focus is within ±2mm
The measurement error between the probe surface and the second focus is within ±2mm
Separate room control and table side control system
Plan and right angle high definition monitor
Infinitely variable control of energy
Discharge frequency range is between0.3~2 second/time and adjust freedom
International control system, long period and gentle touch
*-D mechanical movement: X≤**0mm, Y≤**0mm, Z≤**0mm
Angle of rotation between treatment bed and level, downward *0°
Dip angle of treatment bed, outward *0°        
Maximum capacity of the table ≥**5kG
C arm, small C arm movement cause localization error of second focus ≤±2mm。

国: China
モデル番号: HD.ESWL-V
离岸价格: 10 ~ 30 / ( Negotiable ) Get Latest Price
ロケーション: china
最低注文量の価格: 10
最低注文量: 1 Set
パッケージの詳細: wooden
納期: 30 days
供給能力: 500 Set per Month
支払いタイプ: T/T
製品グループ : -

Send a direct inquiry to this supplier

To:

Ms. Doris < Shenzhen Hyde Medical Equipment Co., Ltd. >

私は知りたい: