Manufacturer: Latakva
Fire Service
Model: LFS WRAP
EI**0
The roll of the fire protection intumescent wrap LFS WRAP comes in
the following dimensions: thickness is 2,5 mm; width is 5 cm;
length is 2,*5 m. The wrap is suitable for pipes with any
diameter.
Fields of
application:
LFS WRAP EI**0 is designed to use in the steel, iron or copper
pipes and also, in the air ventilation ducts which are made from
the steel plates with fire fighting insulation. The wrap can be
used as a seal in the fire rated walls and partitions with the fire
resistance capacity EI **0.
Fire resistance
capacity: EI**0
Conform to: EN
******2:***7+A1:***9
Technical
specifications:
The fire protection
intumescent wrap LFS WRAP can be applied as an insulation material
for pipes which core is made from the synthetic
rubber: AF/Ñmaflex, HT/Ñmaflex, NH/Ñmaflex, Kaiflex
HT, Kaiflex KK, Mondoflex H, HATE-FLEX HT, Optiflex, Concept HT or
analogs.
Main advantages
and benefits:
-
The roll of the fire protection wrap LFS WRAP may be used for
insulation of any fire resistant pipes of any diameter or for
insulation of air ventilation ducts, which are made from the sheet
metal.
-
Apply two layers of the fire protection material around the
insulation of the fire resistant pipe which is installed in the
wall or ceiling or apply five layers of it around pipe so that 5 mm
of the tape should be left outside.
-
Fire protection wraps are designed to be used around fire resistant
pipes of different diameters or for insulation of the regular pipes
or flammable pipes, which are made from sheet metal and with
diameter of up to **0 mm
General
instructions:
In the event of fire the insulation of the fire resistant steel,
copper or iron pipes, which are passing through the walls or
ceiling, can be burned or melted and those creating apertures
between pipes and structures. Fire and smoke is spreading through
the apertures to other neighboring compartments.
Preventing of
fire spread:
-
Apply two layers of the LFS WRAP to both sides of the insulation of
the pipe which is located in the fire resistant walls or ceiling
and 5 mm of the tape should be left outside.
-
In fire conditions, the tape is rapidly expanded and foamed until
the aperture is completely sealed.
-
The application of LFS WRAP onto the flammable pipes (PVC, PE, PP,
REX, etc.) is similar only applying 5 layers of the LFS WRAP,
leaving 5 mm of the tape outside and tightening layers with the
plastic clip.
-
PROMAT coating is used for sealing gaps around tape or fire
resistant mix PROMASTOP® mG III is applied for sealing in the
monolithic walls.