- Compact size and less weight.
- Combined module for *5kw or below with high reliability.
- Reasonable layout with less interference and better
ventilation.
- Combined module with perfect reliability.
- 3 control modes available: VF control, sensorless vector
control, torque control.
- High start torque: 0.5Hz, **0%(vector control)
- *6 steps speed control, simple PLC function, PID function
- 7 digital s(including 1 pulse ), 2 analog and 2
analog output, 2 relay output, 1 open-collector output.
- Automatic output voltage regulation(AVR)
- RS **5 interface(Modbus RTU communication protocol)
- Oscillation suppression function.
- Non-stop at momentary power failure.
- Speed-tracing function.
- *0 kinds of fault protection.
- Output*****0Hz.
- Droop function..
- Energy saving control mode.
Technical specifications
|
|
|
|
|
|
|
|
|
|
|
programmable DI: 7, 1 high speed pulse;
programmable AI:2, VCI:**0V~*0V, CCI2:0~*0V or 0~*0mA
|
|
Programmable open collector output 1(open collector or high speed
pulse output selectable), programmable relay output 2 programmable
AI:2, 0/4~*0mA or 0~*0V selectable
|
|
RS**5
communication interface is optional, adopt Modbus-RTU communication
mode.
|
|
|
V/F
control, sensorless vector control (SVC)
|
|
|
|
**0%
rated current *0s, **0% rated current *0s.
|
Frequency Reference Source
|
Keypad, analog , DI, serial communication, multi-step speed,
simple PLC and PID. The combination of multi-modes and the switch
between different modes can be realized.
|
|
l Traverse Control Function
l PID Control Function
l Simple PLC,Multi-Steps Speed Control Function: *6
steps speed can be set.
l None-Stop when instantaneous power off.
l Speed Trace Function: Smoothly start the running
motor.
l Automatic Voltage Regulation Functin (AVR):
l Up to *3 fault protections over current, over
voltage, under voltage, over temperature, phase failure, overload
etc.
|
|
|
Can
display setting frequency, output frequency, output voltage, output
current etc.
|
|
The
QUICK/JOG key-press can be used as multi-function key-press.
|
|
|
**0°C~**0°C.Inverter will be derated if ambient temperature exceeds
*0°C.
|
|
≤*0%,
without condensation
|
|
≤***0M, output rated power
>***0M, output power with derating
|
Impingement and Osciliation
|
The
inverter is prohibited to drop on the floor or with suddenly
impact, it also prohibited to be installed at the place where the
osciliation may occur very probably.
|
Electromagnetic Radiation
|
The
inverter is prohibited to be installed at the price where stronger
electromagnetic radiation may occur very probably.
|
|
The
inverter is prohibited to be stored at the place where with direct
sunlight, fall of oil mist, steam and with heavy osciliation..
|
|