あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。 今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
Gas turbine and steam turbine Gas turbine and steam turbine Gas turbine and steam turbine Gas turbine and steam turbine Gas turbine and steam turbine
Next

Gas turbine and steam turbine

离岸价格

Get Latest Price

|

- Minimum Order

国:

Spain

モデル番号:

Gas turbine and steam turbine

离岸价格:

Get Latest Price

ロケーション:

-

最低注文量の価格:

-

最低注文量:

-

パッケージの詳細:

-

納期:

Ready to dismantle

供給能力:

-

支払いタイプ:

-

製品グループ :

-

今すぐお問い合わせください
無料会員

連絡先担当者 Mr. Maurici

Corcega, Spain, Other

今すぐお問い合わせください

製品仕様

  • Brand Name: GE LM 2500 PE

タイトルまたは説明

GAS TURBINE

1 Unit
Package manufacturer: European Gas Turbines (EGT)
Model: GE LM****-PE
Power output: *1.**0 kW ISO conditions
Heat Consumption: *1.**6 kW ISO conditions
Fuel: Natural Gas
Start up: ***4
Total running hours: *9.**0 since last overhaul.
Serial nº: ******5
Alternator: GEC Alsthom |3.**0 rpm |*0 Hz |6,3 kV |PF 0,8|Brushless type.
Scope of supply
Generator
Gas Turbine Package
Core Engine
Gas Generator
Air Inlet Casing
Compressor Rotor
Compressor Stator with Variable Guide Vanes
Combustion system
Power Turbine
Hot Gas Interduct
Power Turbine Rotor
Power Turbine Stator
Output Shaft Drive
Exhaust Outlet Casing
Engine Bearing Temperature Instrumentation
Engine Bearing Vibration Instrumentation.
Base plate
Start System - Hydraulic Motor and Pump - AC electric motor driven
Gears, Couplings and Guards
Main speed reducing gearbox - Epyciclic. Including all auxiliaries.
Lubricating Oil System, including main, auxiliary and emergency oil pumps, tanks, oil cooler, filters, etc.
Gas Fuel System, including conducts, fuel flow control system, rapid-acting gas shut-off valves and block and vent valves.
Accoustic Enclosure Ventilation System - *0 dBA at 1 m.
Gas Detection System
Fire Protection System
Fire Fighting sytem
Combustion Air Inlet System, including ducts, silencer and filters.
Combustion Exhaust System, including diffuser and flexible joints.
Package auxiliaries, including turbine compressor cleaning system.
Electrical Systems
Motor Control Center - off-package
Batteries and battery charger.
Control System
Unit Control System - RUSTRONIC MKII.
Generator Control System
Spare parts: List under request

STEAM TURBINE

Engines: 1 Unit
Manufacturer: ALSTOM
Power output: 4.**0 kW
Steam flow: *2 t/h
Steam conditions: *0 *(*)@********************output (min/norm/max): 6/8/*0 bar(g)
Start up: ***6
Total running hours: **4.**0 h
Alternator: ABB |Type: WG**0 |***0 rpm | *0 Hz |6,3 kV |PF 0,8|6.**0 kVA.
Scope of supply
Steam Turbine.
Generator.
Gearbox, supplied by FLENDER-GRAFFENSTADEN
Oil System
Oil tank, ***0l.
Oil vapour suction unit.
Main, auxiliary and emergency oil pumps.
Oil cooler.
Double oil filter.
Injection cooling station.
Auxiliary oil pump.
Emergency
Gas Generator

HEAT RECOVERY STEAM GENERATOR


1 Unit
Manufacturer: BALCKE-DURR
Year ***4 modified in ***0 by DBEMA.
Natural Water Circulation
Location Outdoors
Steam flow (without suplementary firing): *1 t/h
Steam flow (with max. suplementary firing): *9 t/h
Steam pressure: *0,0 bar(g)
Design steam pressure: *8,0 bar(g)
Steam temperature: **0ºC
Feed stack water temperature: *****5ºC
Exhaust temperature: **6ºC
Burner manufacturer: ECLIPSE VAI C****0
Burner Power: *3 MW, range 1:*0

Scope of supply
Pressure parts.
HP Final superheater
HP Primary superheater
HP Evaporator
HP Economizer
Water Preheater.
Ducts and stacks .
Damper supplied by STEJASA.
Burner supplied by ECLIPSE
Deaerator and feedwater tank, *5 m3.
Feedwater pumps, 2 units, supplied by SULZER. *8,7m3/h | **8 m
Chemical dosing system.
Blowdown system. 1m3 tank.
BMS and control system.

HIGH VOLTAGE AND LOW VOLTAGE SYSTEM


Outdoor substation *0 kV.
Power transformers and auxiliary services transformer.
Gas turbine: *0,0 MVA | *0 kV*6,3 kV | Ynd *1 | Manufacturer OASA
Steam turbine: 6,5 MVA | *0 kV*6,3 kV | DYn *1 | Manufacturer OASA
For auxiliaries: 2,0 MVA | 6,3 kV*0,4 kV | DYn *1 | Manufacturer OASA
MV switchgears
Motor control center
Protections cabinets
MV cables between switchgears, generators and power transformers.

NATURAL GAS STATION

Max flow: 7.**0 Nm3/h
Inlet pressure: *2 bar
Outlet pressure: *2 bar for GT | 2,5 bar for burner.

WATER TREATMENT

Demineralised water plant
Capacity: **0 m3/*4 hours.
Ion-exchange, DOW-UPCORE system.
Neutralization tank, *0 m3