High pressure Garbage incineration power plant blower fan High pressure Garbage incineration power plant blower fan High pressure Garbage incineration power plant blower fan
Next

High pressure Garbage incineration power plant blower fan

离岸价格

Get Latest Price

600 ~ 8000 / Unit

|

1 Unit Minimum Order

国:

China

モデル番号:

XTS-2014

离岸价格:

600 ~ 8000 / Unit Get Latest Price

ロケーション:

-

最低注文量の価格:

600 per Unit

最低注文量:

1 Unit

パッケージの詳細:

wooden package or as customers' requirements

納期:

10-25days after receiving deposit from buyers

供給能力:

200 Unit per Month

支払いタイプ:

Other, L/C, T/T

製品グループ :

今すぐお問い合わせください
無料会員

連絡先担当者 roy

DaZhaoYing, Xinxiang, Henan

今すぐお問い合わせください

製品仕様

  • Type:Centrifugal fan
  • Mounting:Free Standing
  • Medium temperature:0~250°C
  • Driving Mode:Coupling
  • Total Pressure:2705~16250Pa
  • Brand Name:Hengtong

タイトルまたは説明

Details of blowers
1. Applications
 This type of  fans are generally used for the air conveying and draughting of different types of  cement  plant.
 
2. Structure
   Main parts: Case, Impeller, Motor, protective screening.
 fans can be divided into*0 specifications according to the impeller angle,  each type of blades can be mounted by *5°, *0°, *5°, *0°, *5°
 
3. Production Parts:
The standard configuration of this type of fans are generally consist of the following product parts:
case, impeller, air inlet, motor, system integral pedestal, main shaft, driving system (bearing house, bearing), coupling
4.blower Characteristics
•Optional Parts: flexible coupling, variable inlet vane damper, damper, electric actuator, motor with variable frequency and speed regulation, frequency converter, soft starter for motor;
•Impeller is adjusted by the static and dynamic balancing test.
•Backward blades
•Water cooled bearing house
•Oil leak preventing design for bearing house
•Long service life
•Large air volume, low noise, high efficiency and abration resistant
•Easy installation and operation, LAPU.
•Superior service in customized design and production.
 
 
5.  maintenance of blowers
Blowers can run based on complete normal conditions
Please check every part of blower is regular or not after repairing.
Clearing fan and gas pipeline internal dust at regular period, dirt and impurities such as water, and to prevent rust
Repairing cannot going at running period.
6. Notes
If the discovery of flow is too large, and not fit for the request or short time need to smaller flow, can use the throttle device adjusted.
Inspect the thermometer and oil mark sensitivity at regular period.
If there is off-normal occurrence happen when blower drive, stop and rotate,should repair it as soon as possible.
if there is small glitch, should check it, and repair it.
In addition to every time after repairing should be oil change outside, still should be regularly oil change
 7. Quality control procedure
Material strength test, Material composition analysis, Dimension inspection, 
Ultrasonic weld inspection, Dynamic balancing test, Running vibration measuring, 
Running noise measuring, Paint thickness measuring, Performance test.
8. Certificate
ISO***1
9. Export Record:
Romania, Saudi Arabia, Egypt, Iran, Philippine, Vietnam ,Russia and so on
*0. Order Requirement:
We will appreciate it a lot if you can offer us your product performance requirements and operation environment, so that we can customize optimal production to meet your every requirement.
1) Air volume
2) Total Pressure or Static Pressure
3) Voltage and Frequency
4) Medium Temperature and Density
5) Altitude of Operation Place
*2. Installation requirement:
1.       when Install the blower, the weight of the gas transmission pipeline should not be add in the casing, according to the drawings corrective air inlet and impeller gap between size, and keep axis horizontal position
2.       When Install air inlet pipe, you can directly use air inlet itself bolt connection, the air inlet of fixed by three countersunk screw
3.       Diffuser be installed into a certain Angle, back cover properly rotary can keep plate in a horizontal position.
4.       After installation, rotating rotor by hand or lever, checking whether there is too close or collision phenomenon, in the absence of these phenomena when square test run
If you are interest the blower can contact us anytime, We will do our best for you! Sincerely hope that we can cooperate future! 

 

国: China
モデル番号: XTS-2014
离岸价格: 600 ~ 8000 / Unit Get Latest Price
ロケーション: -
最低注文量の価格: 600 per Unit
最低注文量: 1 Unit
パッケージの詳細: wooden package or as customers' requirements
納期: 10-25days after receiving deposit from buyers
供給能力: 200 Unit per Month
支払いタイプ: Other, L/C, T/T
製品グループ : power blower

Send a direct inquiry to this supplier

To:

roy < Henan Hengtong Blower Co., Ltd >

私は知りたい: