タイトルまたは説明
Phase:
3
Accuracy
class: 0.*5 or 0.1
AC voltage
output: *****0V
AC current
output: ***6A
DC voltage
output: *****0V
DC current
output:***0A
This rugged Meter Test System is composed of
high accurate (class 0.*5% or 0.1%) standard reference meter and
power source (up to *6A). This system is particularly designed
for modular structure for calibration and test of analog meter,
digital meter, RTU, electrical transducer, energy meter and so
on.
It is operated under high functionality with
user friendly interface.
Feature
-
Integration
of high accurate reference meter and reliable power
source
-
Eligible to
calibrate indicating meter, electrical transducer, energy
meter, RTU and so on
-
Accuracy:
U, I, P, kWh: ±0.*5%; Q, kvarh : ±0.1%
-
U, I, P
stability: 0.*1%RG/3min; Distortion of AC Voltage and AC
Current: ≤ 0.2%
-
Measurement
Scope:
AC Voltage:
**0mV~***0V (Single phase), *7.7V~**0V (3
phase)
AC Current:
2mA~*0A (Single phase), 0.2A~*0A (3
Phase)
DC Voltage:
*5mV~**0V; DC Current: **0μA~*0A
-
Export
2nd**3rd harmonics, and measure & analyze the
harmonics
-
With relay
output and pulse output, MTS***2 remotely controls tests of
indication and information response time
-
Modular
design with 8 color TFT screen and user-friendly interface,
easy to operate
-
Automatic
Calibration System can be customized according to customer's
requirements
-
Exchange
the testing settings and testing records thru
USB
-
Remotely
updating online, easily achieve software
updating
-
With
connectors of RS***2, RS***5, I/O, Ethernet, USB and
WiFi, convenient for PC operation, firmware update and remote
diagnosis.
-
Self-protection, alarming and displaying
overload location for equipment output overload, Voltage
short-circuit, Current open-circuit
-
Self-diagnosis for amplifier failure and
internal module communication failure
-
Test energy
meters with the accuracy of Class 0.2 and below (Class 0.*5
equipment)
Technical
Specification
AC large
Voltage output:
Range: (L1)
*0V, **0V, **0V, **0V, ***0V;
(L2 &L3) *0V, **0V, **0V,
**0V;
Adjusting
range: (0~**0) %RG, RG refers to
range, similarly hereafter; L1 ***0V: (0~**0)
%RG;
Adjusting
degree: 0.*1%RG, 0.1%RG, 1%RG, and *0%
RG
Stability:
0.*1%/2min
(Class 0.*5), 0.*2%/2min (Class 0.1)
Distortion:
≤0.2% (Non capacitive
load);
Max output
load: *0V and upper gears; *0VA each
phase;
Measurement
accuracy: 0.*5%RG (Class 0.*5); 0.1%RG (Class
0.1)
AC small
Voltage output:
Range: L1:
*5mV, **0mV, **0mV, 3V, 7.5V;
Adjusting
range: (0~**0) %RG, RG refers to range;
Adjusting
range: 0.*1%RG, 0.1%RG, 1%RG, and *0% RG for
option;
Stability:
0.*2%/2min;
Distortion:
≤0.2% (Non capacitive load);
Max output
load: ≥*5mA;
Measurement
accuracy: 0.1%RG;
AC Current
output:
Range: (L1)
2mA, 2mA,*0mA, *0mA, **0mA, **0mA, 2A, 5A, *0A,
*0A;
(L2 & L3)
**0mA, **0mA, 2A, 5A, *0A, *0A;
Adjusting
range: (0~**0) %RG, RG refers to range, similarly
hereafter;
Adjusting
degree: 0.*1%RG, 0.1%RG, 1%RG, and *0% RG for
option;
Stability: 0.*1%/2min (Class 0.*5),
0.*2%/2min (Class 0.1)
Distortion:
≤0.2% (Non capacitive load);
Max output
load: *0VA (*0A gear); *0mA and below gear:
≥*5V;
Measurement
accuracy: **0mA and above gears: 0.*5%RG (Class 0.*5); 0.1%RG
(Class 0.1);
*0mA and below gears: 0.1%RG (Class
0.1);
Power
output
Power output
stability: 0.*1%/2min (Class 0.*5), 0.*2%/2min (Class
0.1)
Active/reactive
power measurement accuracy: 0.*5%RG;
Phase
output
Output
adjusting range: 0°~**0°;
Output
adjusting degree: *0°, 1°, 0.1°, 0.*1° for
option;
Resolution:
0.*1°;
Measurement
accuracy: 0.*5°.
Power factor
output:
Adjusting
range: *1 ~ 0 ~ *1;
Measuring
resolution: 0.***1;
Measurement
accuracy: 0.***5
Frequency
output
Adjusting
range: *0Hz ~*0Hz;
Output
adjusting degree: 1Hz, 0.1Hz, 0.*1Hz, 0.**1Hz for
option;
Resolution:
0.**1Hz;
Accuracy: 0.**2
Hz.
Harmonic
setting
Harmonic times:
2nd ~*3rd;
Harmonic
content: 0~*0%
Harmonic phase:
0°~**9.*9°
Harmonic set
error: 2nd ~*1st times:
≤±0.1%,*2nd ~*3rd times:
≤±0.2%ï¼›
DC Voltage
output
Range: **0mV, **0 mV, 1V, 5V, *0V,
**0V, **0V, ***0V;
Adjusting
range: (0~**0) %RG; ***0V: (0~**0)
%RG
Adjusting
degree: 0.*1%RG, 0.1%RG, 1%RG, and *0%
RG;
Stability:
0.*1%/2min (Class 0.*5), 0.*2%/2min (Class
0.1)
Output load:
≥*0mA;
Measurement
accuracy: 0.*5%RG (Class 0.*5); 0.1%RG (Class
0.1)
Ripple content:
no more than 1%.
DC Current
output
Range: **0μA,
**0μA, 1mA, 3mA, *0mA, *0mA, **0mA, **0mA, 1A, 5A, *0A, *5A,
*0A;
Adjusting
range: (0~**0) %RG;
Adjusting
degree: 0.*1%RG, 0.1%RG, 1%RG, and *0%
RG;
Stability:
0.*1%/2min (Class 0.*5), 0.*2%/2min (Class
0.1)
Output load:
*5A: *5VA; 5~*0A: 2V; 1A and lower gear
≥*0V;
Measurement
accuracy: 0.*5%RG (Class 0.*5); 0.1%RG (Class
0.1)
Ripple content:
no more than 1%.
DC
Voltage measurement
Range:
±*0V;
Measuring
range: (****0) %RG;
Basic error
limit: 0.*2%RG
Ripple
measuring error: (5%RD + 0.1%), RD refer to ripple measured
value;
Resolution:
0.**1%RG.
DC
Current measurement
Range:
±*0mA;
Measuring
range: (****0) %RG;
Basic error
limit: ±0.*2%RG
Ripple
measuring error: ± (5%RD + 0.1%), RD refer to ripple measured
value;
Resolution:
0.**1%RG.
Energy error
measurement:
Active energy
basic error limit:
0.*5%RD (Voltage *5V~**0V,
Current 0.*5A~*6A, PF≥0.5);
0.1%RD (Voltage
*5V~**0V, Current 0.*2A~0.*5A, PF=1);
Reactive energy
basic error limit:
0.1%RD (Voltage
*5V~**0V, Current 0.*5A~*6A, PF≥0.5);
0.2%RD (Voltage
*5V~**0V, Current 0.*2A~0.*5A, PF=1);
Other
parameters:
Power
supply: *****5VAC/DC
Power
frequency: *0Hz~*0Hz
Power
consumption: *0VA~***0VA
Working
environment: *0℃~*0℃,Humidity:
RH≤*5%
Storage
environment: **0℃~*0℃
Size: **0(L)×
**0 (W)× **6(H)mm
Weight: *0kg
国: |
China |
モデル番号: |
MTS-122
|
离岸价格: |
(交渉可能)
Get Latest Price
|
ロケーション: |
- |
最低注文量の価格: |
- |
最低注文量: |
- |
パッケージの詳細: |
- |
納期: |
- |
供給能力: |
- |
支払いタイプ: |
- |
製品グループ : |
- |