NA8634-A Heat Pump Thermostat
Next

NA8634-A Heat Pump Thermostat

离岸价格

Get Latest Price

47.5 ~ 50 / Set ( Negotiable )

|

10 Set Minimum Order

国:

China

モデル番号:

NA8634-A

离岸价格:

47.5 ~ 50 / Set ( Negotiable ) Get Latest Price

ロケーション:

China

最低注文量の価格:

47.5 per Set

最低注文量:

10 Set

パッケージの詳細:

Each set per polybag, then in white box.

納期:

15days

供給能力:

10000000 Set per Year

支払いタイプ:

T/T, L/C

製品グループ :

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Rita

No.2Newasia RD.Huaqiang Industrial Zone.Taicang City,Jiangsu,China, Wuxi, Jiangsu

今すぐお問い合わせください

製品仕様

  • Brand Name: NEWASIA
  • Installation:Wall Hanging:Silver grey

タイトルまたは説明

                                 NA***7 User Guide Main Function and Control Logic: The temperature testing has two channels: one is at the water inlet, as the temperature controlling signal,the other is at the water outlet, used for preventing frostbite. Four output channels: compressor, cooling water pump, freezing water pump, alarm output. Three switching value s (passive point signal): cooling water pressure switch, freezing water pressure switch, on-off signal. Control Logic: 1. On/off The controller can start up or shut down with the on-off key on the panel or external switch, the light of the "power supply" lights in the on state and extinguishes in the off state. 2. Refrigeration When it begins to refrigerate, the controller will first turn on the cooling water pump, and then turn on the compressor when the cooling water pump switch is close. When it stops refrigeration, the controller will shut off the compressor and cooling water pump. The freezing water pump is always running in the on state. 3. Water lack alarm Check whether the cooling water and the freezing water is normal by water pressure switch, if the freezing water is lacking in the on state, the controller will turn off the freezing water pump and give an alarm and can not turn on refrigeration. If the freezing water or cooling water is lacking in the refrigerating state, the system will stop and give an alarm. 4. Frostbite preventing If the water out temperature of the freezing water is below3C, the controller will stop refrigeration, but the freezing water pump is still running, the state will resume when the temperature goes up to 5C. (The alarm temperature and the resume temperature are adjustable, and please refer to the senior operation) Technique Index: Temperature display range:**0~**5C, step 0.1C Temperature setting range: **5~**0C Power supply: *2V AC (Use the transformer with the controller,primary voltage, **0V±*0% or **0V±*0%) Operation Environment: temperature **0C~*5C, humidity≤*5%. Without congealed hoarfrost. Relay contact capability: 2A/*50VAC (Pure resistive load) Temperature sensor: NTC R*5=5kΩ, B (*5/*0) =***0K Executive standard: Q/*****5 XYK *1 (NA***7-CTAX)

国: China
モデル番号: NA8634-A
离岸价格: 47.5 ~ 50 / Set ( Negotiable ) Get Latest Price
ロケーション: China
最低注文量の価格: 47.5 per Set
最低注文量: 10 Set
パッケージの詳細: Each set per polybag, then in white box.
納期: 15days
供給能力: 10000000 Set per Year
支払いタイプ: T/T, L/C
製品グループ : Thermostat