あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。 今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
product
Prev
New LC 013 LCF 013 Airflow Monitor Sensor
Next

New LC 013 LCF 013 Airflow Monitor Sensor

离岸价格

Get Latest Price

9 ~ 12 USD / Piece ( Negotiable )

|

100 Piece Minimum Order

国:

China

モデル番号:

-

离岸价格:

9 ~ 12 USD / Piece ( Negotiable ) Get Latest Price

ロケーション:

-

最低注文量の価格:

9 per Piece

最低注文量:

100 Piece

パッケージの詳細:

Standard export packing

納期:

Sample orders 1-3 days, bulk orders 3-15 days

供給能力:

1000 Piece per Week

支払いタイプ:

T/T, L/C, Western Union, PayPal

製品グループ :

今すぐお問い合わせください
無料会員

連絡先担当者 Leo

Wenzhou, Zhejiang

今すぐお問い合わせください

製品仕様

  • Contact type:reed / magnet contact

タイトルまたは説明

New LC **3 LCF **3 Airflow Monitor Sensor
 

■ Mechanical switch contact 
â–  Versatile fields of application
â–  Small size
â–  Easy to connect
 
The airflow monitor (NC/NO) is designed to indicate the loss of air movement of a fan or filter fan. The contact detects the loss of air movement caused by fan failure or blocked filter media regardless of direction of air. Its simple mechanical operation makes is a viable alternative to electronic monitoring systems.
 
Application:
The LC **3 is used as a signal contact to monitor fans or filter fans in stationary, self-contained Protection Class I enclosures. It can be connected to monitoring systems with remote control or can directly switch alarm devices, such as LED’s or signal lamps. Loads with capacities exceeding the indicated switching capacity must be switched via a relay, e.g. our electronic relay SM **0. The airflow monitor with NC contact closes upon loss of air movement, i.e. it indicates fan failure (e.g. red signal lamp). The NO contact closes when fan is in operation and serves as optical function display (e.g. green signal lamp).
 
 
â–  Technical Data
Contact type reed / magnet contact
Normally Closed (NC) switch contact open when air is flowing
Normally Open (NO) switch contact closed when air is flowing
Max. switching voltage NC: **0VDC (UL), **0V AC/DC (VDE) / NO: *0VDC
Max.switching current NC: DC **0mA / NO: DC **0mA
Max. switching capacity *0W (resistive load)
Switching threshold of airflow velocity >2.5m/s (hysteresis:>1m/s)
Max.airflow velocity *0m/s
Contact resistance <**0m (with wire)
Max. air humidity *0% RH (not precipitating)
Service life >**0,**0 cycles
Connection 2×single strand AWG*6, length **0mm, tip of stranded 
wire 5mm stripped and tinned (NC:black, NO:blue)
Mounting alternatively integrated integrated in protective grille (see table).
mounting clamp or mounting clip
Casing plastic according to UL**-HB, black
Fitting position bidirectional tab perpendicular to airflow
Operating / Storage temperature **0 to **0℃ (*4 to ***2°F) / **0 to **0℃ (*4 to ***6°F)
Protection type IP*0
Note: The product of switching voltage and switching current must not exceed *0W. The max. voltage and max. current must not be exceeded, not even short-term (voltage/current peaks). The resulting voltage and current peaks of inductive or capacitive loads must be restricted by a contact protection circuit.

■ Mechanical switch contact 
â–  Versatile fields of application
â–  Small size
â–  Easy to connect
 
The airflow monitor (NC/NO) is designed to indicate the loss of air movement of a fan or filter fan. The contact detects the loss of air movement caused by fan failure or blocked filter media regardless of direction of air. Its simple mechanical operation makes is a viable alternative to electronic monitoring systems.
 
Application:
The LC **3 is used as a signal contact to monitor fans or filter fans in stationary, self-contained Protection Class I enclosures. It can be connected to monitoring systems with remote control or can directly switch alarm devices, such as LED’s or signal lamps. Loads with capacities exceeding the indicated switching capacity must be switched via a relay, e.g. our electronic relay SM **0. The airflow monitor with NC contact closes upon loss of air movement, i.e. it indicates fan failure (e.g. red signal lamp). The NO contact closes when fan is in operation and serves as optical function display (e.g. green signal lamp).
 
 
â–  Technical Data
Contact type reed / magnet contact
Normally Closed (NC) switch contact open when air is flowing
Normally Open (NO) switch contact closed when air is flowing
Max. switching voltage NC: **0VDC (UL), **0V AC/DC (VDE) / NO: *0VDC
Max.switching current NC: DC **0mA / NO: DC **0mA
Max. switching capacity *0W (resistive load)
Switching threshold of airflow velocity >2.5m/s (hysteresis:>1m/s)
Max.airflow velocity *0m/s
Contact resistance <**0m (with wire)
Max. air humidity *0% RH (not precipitating)
Service life >**0,**0 cycles
Connection 2×single strand AWG*6, length **0mm, tip of stranded 
wire 5mm stripped and tinned (NC:black, NO:blue)
Mounting alternatively integrated integrated in protective grille (see table).
mounting clamp or mounting clip
Casing plastic according to UL**-HB, black
Fitting position bidirectional tab perpendicular to airflow
Operating / Storage temperature **0 to **0℃ (*4 to ***2°F) / **0 to **0℃ (*4 to ***6°F)
Protection type IP*0
Note: The product of switching voltage and switching current must not exceed *0W. The max. voltage and max. current must not be exceeded, not even short-term (voltage/current peaks). The resulting voltage and current peaks of inductive or capacitive loads must be restricted by a contact protection circuit.
 
Installation notes:
1. The airflow monitor must not be installed in the impact range of permanent magnets or ferrous metals as the built-in permanent magnet will move unintentionally and consequently can not move in dependence with the air flow.
2. A suitable distance from electromagnetic fields, e.g. generated by transformers, motors, etc., must be maintained as otherwise the contact may switch incorrectly with the frequency of the power supply. Interferences must be checked with an oscillograph and the mounting position of the airflow monitor should be adjusted if necessary. 
3. Avoid installing the airflow monitors in areas where air pockets or turbulence can be expected.
4. Ambient air with a high dust contect should be avoide.
As there are many different conditions of use, suitability of this product must be assessed by the end user in its final application.
 
Description Art. No. (NC) Art. No. (NO) Dimensions Weight (approx.)
Airflow monitor with mounting clamp and mounting clip LC **3 ****0.***0 ****0.***0 *4×*7.5×7.5mm 5g
Airflow monitor integrated in protective grille (plastic) LCF **3 ****1.***0 ****1.***0 *0×*8×*0.5mm *0g
****2.***0 ****2.***0 *2×*2×*0mm *0g
****3.***0 ****3.***0 **0×**0×*0mm *0g

国: China
モデル番号: -
离岸价格: 9 ~ 12 / Piece ( Negotiable ) Get Latest Price
ロケーション: -
最低注文量の価格: 9 per Piece
最低注文量: 100 Piece
パッケージの詳細: Standard export packing
納期: Sample orders 1-3 days, bulk orders 3-15 days
供給能力: 1000 Piece per Week
支払いタイプ: T/T, L/C, Western Union, PayPal
製品グループ : Sensor

Send a direct inquiry to this supplier

To:

Leo < Yueqing Xingyang Electronic Co.,LTD >

私は知りたい: