タイトルまたは説明
Detection method:
Adopts the half-cell potential method to
test the rebar corrosion condition in the concrete structure;
adopts the Wenner sensor (Spacing is *0mm) to test the concrete
resistivity
Detector:
concrete rebar corrosion potential,
concrete resistivity
Standard:
GB/T*********4 Technical standard for
inspection of building structure
JGJ/T *******8 Technical specification
for test of reinforcing steel bar in concrete
Application:
The equipment can test the rebar
corrosion potential in the concrete structure based on the
potential testing mode, and it can test any structure with
different surface area and direction. Under the concrete
resistivity testing mode, the equipment can test the resistivity to
evaluate the corrosion possibility in concrete structure. Both
methods can evaluate the rebar corrosion possibility in the
concrete structure.
Feature:
1. Twomethods for rebar corrosion
potential testing( direct method and gradient method) are suitable
to different test field.
2. 0~***0 kΩ cm large range concrete
resistivity testing
3. Large touch color screen to display
and control, convenient usage, and additional keyboard for
ting
4. The screen can display corrosion
potential color histogram directly, the user can evaluate the
corrosion degree onsite quickly.
5. Multi-functional PC can store and
process the data.
6. Rechargeablelithium batteries
to ensure long working hours
7. Mini printer for printing
directly.
Parameter:
Range: 0~***0 kΩcm,±***0mV
Display resolution: 0.1
kΩcm,1mV
Storage: **8 groups
PC communication parameter: *****0 baud
rate
LCD : **0***0
Host dimension: **0***5**0mm
Host weight:1.5kg
System
configuration:
Concrete resistivity and rebar
corrosion tester
Wenner sensor, saturated copper sulfate probe
Resistivity standard
mould
AC adapter
Superconducting sponge
plug
Connecting cable and
line
Mini-printer and
charger
PC software and data