Super External Counter-Pulsation Device (SECP III)
Next

Super External Counter-Pulsation Device (SECP III)

离岸价格

Get Latest Price

|

1 Acre Minimum Order

国:

China

モデル番号:

SECP III

离岸价格:

Get Latest Price

ロケーション:

china

最低注文量の価格:

-

最低注文量:

1 Acre

パッケージの詳細:

-

納期:

30 day

供給能力:

-

支払いタイプ:

T/T, L/C

製品グループ :

-

今すぐお問い合わせください
無料会員

連絡先担当者 Mr. EECP

NO.18, 2nd Hanxi Industrial Zone, Zhongcun, Panyu, Guangzhou, China, Guangzhou, Guangdong

今すぐお問い合わせください

タイトルまたは説明


Product: Super External Counter-Pulsation Device (SECP)
USAGE:

The device can be used for the treatment of: Technical Specification

1. Common mode rejection ratio (CMRR): not less than *0 dB(resolution).
2. Automatic pick-out of the QRS, gating limit at the terminal, not greater than 0.*5 mV. Both positive and negative EC can be detected.
3. Automatically tracing the irregular heart rate, and making possible synchronized counter-pulsation.
4. In case of premature pulsation or delayed deflation, QRS wave triggers the deflation automatically.
5. In case of patient's heart rate is lower than *2 beats/min., the parameter of heart rate on screen becomes red and the ECPT stops automatically, ECPT recovers when the heart rate is normal.
6. At "ADULT" , in case of premature pulsation or the patient's heart rate exceeds **5 beats/min., the parameter of heart rate on screen becomes red and the ECPT stops automatically, and ECPT recovers when the heart rate is normal.
7. The device has 5 adjustable settings for simulated EC waves (inner triggering square waves) i.e. *0,*0,*0,**0,**0 beats/min.. In case of turning on or reset, the default setting is *0 beats/min..
8. The device has 9 adjustable settings for treating time, i.e. *0,*0,*0,*0,*0,*0,*0,*0,*0 minutes. In case of turning on, reset or restoration of power supply, the default setting is *0 minutes.
9. The monitor displays:
(1)Heart rate and starting time of inflation and deflation.
(2)Treating time, pulse wave peak ratio: h2 : h1 and area ratio: Area 2 : Area 1.
*0. Two settings for counter-pulsation ratio: 1:1 : 1:2.
*1. Digital filtering restrains the sine *0 Hz interference signals from EC .
*2.*-trace,*-signal monitor displays the cardiac signal,inflation/deflation signal and pulse waveform synchronously.
*3. Limiting inflation time against positive pulsation function is provided.
*4. 2 scanning speed settings: *5mm/s and *0 mm/s are provided.
*5. Electric-control of pressure regulation.
*6. Automatic stop of the pump at the end of treatment.
*7. Automatic deflation at the end of the treatment.
*8. Power consumption:

    Control Console    : **0V  *0/*0Hz     **0W 
                               **0V  *0/*0Hz    ***0W

Air pump(in the bed)   : **0V  *0/*0Hz    ***0W

*9. The inflation range (positive pressure) is  not lower than  **0.*4MPa, negative pressure is used for deflation.
*0. Upper limit of air-pressure automatically controlled.
*1. The turn-off s for patient in emergency are fitted at each side of the device.

PRINCIPLE

During the treatment, the specially made inflatable balloon cuffs are wrapped and fastened to the extremities and buttocks of the patient. When the heart in the diastolic stage, the air goes into the balloons in sequence, and compresses the artery by cuffs, so that the blood in diastolic stage can concentrate to the upper part of the body, which increase the blood volume of the heart, and promote the set up of the collateral circulation gradually. After the close of arterial valves, through the deflation of the air in the balloon cuffs, the compressed artery is thus immediately release, so that  it may receive the blood driven from the heart, hence the device decreases the after-load of the heart, and reduces the systolic pressure, which has the therapeutic effect on all kinds of cardiac vascular and cerebrovascular diseases caused by myocardial and cerebral ischemia.

Enhanced External Counterpulsation (EECP), therapy

(1).Coronary heart disease, angina pectoris and myocardial infarction.
(2).Cerebral arteriosclerosis, cerebral thrombosis, cerebral embolism, paralysis agitation, cerebral ischemia of vertebral-basilar artery, sequel of cerebrovascular accident and other encephalopathy caused by ischemia.
(3).Embolism of retinal artery, central serous retinopathy, and optic atrophy and nerve disease for shortage of blood.
(4).Sudden deafness.
(5).Other ischemic diseases and sequels caused by arteriosclerosis and disturbance of circulation, therapy after operation of coronary bypass.
(6).Tiredness due to excessive physical exercise.
(7).Rehabilitation and health-care purposes.

国: China
モデル番号: SECP III
离岸价格: Get Latest Price
ロケーション: china
最低注文量の価格: -
最低注文量: 1 Acre
パッケージの詳細: -
納期: 30 day
供給能力: -
支払いタイプ: T/T, L/C
製品グループ : -

関連製品 Guangzhou Yidian Medical Equipment Co., Ltd.

Send a direct inquiry to this supplier

To:

Mr. EECP < Guangzhou Yidian Medical Equipment Co., Ltd. >

私は知りたい: