Product: Super External
Counter-Pulsation Device (SECP)
USAGE:
The device can be used for the treatment of: Technical Specification
1. Common mode rejection ratio
(CMRR): not less than *0 dB(resolution).
2. Automatic pick-out of the QRS, gating limit at the
terminal, not greater than 0.*5 mV. Both positive and negative EC
can be detected.
3. Automatically tracing the irregular heart rate, and making
possible synchronized counter-pulsation.
4. In case of premature pulsation or delayed deflation, QRS wave
triggers the deflation automatically.
5. In case of patient's heart rate is lower than *2 beats/min.,
the parameter of heart rate on screen becomes red and the ECPT
stops automatically, ECPT recovers when the heart rate is
normal.
6. At "ADULT" , in case of premature pulsation or the patient's
heart rate exceeds **5 beats/min., the parameter of heart rate on
screen becomes red and the ECPT stops automatically, and ECPT
recovers when the heart rate is normal.
7. The device has 5 adjustable settings for simulated EC waves
(inner triggering square waves) i.e. *0,*0,*0,**0,**0 beats/min..
In case of turning on or reset, the default setting is *0
beats/min..
8. The device has 9 adjustable settings for treating time, i.e.
*0,*0,*0,*0,*0,*0,*0,*0,*0 minutes. In case of turning on, reset
or restoration of power supply, the default setting is *0
minutes.
9. The monitor displays:
(1)Heart rate and starting time of inflation and deflation.
(2)Treating time, pulse wave peak ratio: h2 : h1 and area ratio:
Area 2 : Area 1.
*0. Two settings for counter-pulsation ratio: 1:1 : 1:2.
*1. Digital filtering restrains the sine *0 Hz interference
signals from EC .
*2.*-trace,*-signal monitor displays the cardiac
signal,inflation/deflation signal and pulse waveform
synchronously.
*3. Limiting inflation time against positive pulsation function
is provided.
*4. 2 scanning speed settings: *5mm/s and *0 mm/s are
provided.
*5. Electric-control of pressure regulation.
*6. Automatic stop of the pump at the end of treatment.
*7. Automatic deflation at the end of the treatment.
*8. Power consumption:
Control
Console : **0V
*0/*0Hz **0W
**0V
*0/*0Hz ***0W
Air pump(in the bed) : **0V *0/*0Hz ***0W
*9. The inflation range (positive
pressure) is not lower than **0.*4MPa, negative
pressure is used for deflation.
*0. Upper limit of air-pressure automatically controlled.
*1. The turn-off s for patient in emergency are fitted at
each side of the device.
PRINCIPLE
During the treatment, the
specially made inflatable balloon cuffs are wrapped and fastened
to the extremities and buttocks of the patient. When the heart in
the diastolic stage, the air goes into the balloons in sequence,
and compresses the artery by cuffs, so that the blood in
diastolic stage can concentrate to the upper part of the body,
which increase the blood volume of the heart, and promote the set
up of the collateral circulation gradually. After the close of
arterial valves, through the deflation of the air in the balloon
cuffs, the compressed artery is thus immediately release, so
that it may receive the blood driven from the heart, hence
the device decreases the after-load of the heart, and reduces the
systolic pressure, which has the therapeutic effect on all kinds
of cardiac vascular and cerebrovascular diseases caused by
myocardial and cerebral ischemia.
Enhanced External Counterpulsation (EECP), therapy
(1).Coronary heart disease, angina pectoris and myocardial
infarction.
(2).Cerebral arteriosclerosis, cerebral thrombosis, cerebral
embolism, paralysis agitation, cerebral ischemia of
vertebral-basilar artery, sequel of cerebrovascular accident and
other encephalopathy caused by ischemia.
(3).Embolism of retinal artery, central serous retinopathy, and
optic atrophy and nerve disease for shortage of blood.
(4).Sudden deafness.
(5).Other ischemic diseases and sequels caused by
arteriosclerosis and disturbance of circulation, therapy after
operation of coronary bypass.
(6).Tiredness due to excessive physical exercise.
(7).Rehabilitation and health-care purposes.