Surface Area and Pore Size Distribution Analyzer
Next

Surface Area and Pore Size Distribution Analyzer

离岸价格

Get Latest Price

( Negotiable )

|

1 Set Minimum Order

国:

China

モデル番号:

JW-BK200B

离岸价格:

( Negotiable ) Get Latest Price

ロケーション:

Beijng, China

最低注文量の価格:

-

最低注文量:

1 Set

パッケージの詳細:

-

納期:

30 days

供給能力:

1000 Set per Year

支払いタイプ:

Other, PayPal, D/P, L/C, T/T

製品グループ :

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Wendy

A Block,No.23,South Binhe Road, Beijing, Beijing

今すぐお問い合わせください

製品仕様

  • Brand Name: JW-BK200B

タイトルまたは説明

Test principle: the static volumetric method, gas adsorption;
Analysis Models: BET, Langmuir, BJH, t-plot, DR, αs-plot, MP, HK, SF, and NLDFT;
Measuring range: surface area ≥ 0.**5M2/g, no upper limit; mesoporous and macroporous 2 _ **0nm; micropore size 0.*5nm _ 2nm; pore volume 0.***1 cm3/g, no upper limit.
Sorption gas:N2 (high purity); Ar, Kr, CO2, CH4, etc. available
Analysis Stations: 2 ports. One analysis station can test the micropore and the other can test the mesorpore.
Sample Type: powders, granules, fibers, flakes and other materials
Pressure Sensor: ***0torr (**3kpa), *0torr (1.*3kpa); 1torr (0.**3kpa) or 0.1torr (0.***3kpa); accuracy≤± 0.*5%(P.S)
P0 tube: there is a separate P0 tube in every analysis port, two in all, controlled by a separate pressure sensor, completely separates from the analysis port, real-time detecting the nitrogen saturation vapor pressure, and participating in the theoretical calculation; also the atmospheric method to determinate the P0 accurately;
Cold trap tube: sample degassing system has a special cold trap device that can effectively remove the water, hazardous substances and other impurities, degassed from the special sample, and it can avoid the contamination of the vacuum system;
Degassing system: Parity, ectopic vacuum degassing pretreatment systems are controlled by separate pressure sensors. Two samples can be analyzed simultaneously, also two samples can be degassed in degassing ports; two independent sample degassing stations are separate from the sample analysis ports. The degassing system has two independent heating packages, two independent temperature control systems, which can be programmed by temperature control; you can choose another four external vacuum degassing pretreatment system;
Degassing temperature: room temperature ***0℃, accuracy ± 1℃;
Nitrogen Partial Pressure: P/Po 1×***8 _ 0.**8, the minimum resolvable relative pressure 5 × ***7
Ultimate vacuum:≤ *0P*6 Pa(7.5×***9 torr), mechanical pump and turbo molecular pump.
Pressure Accuracy: ≤ ± 0.*5% (P.S)
 

国: China
モデル番号: JW-BK200B
离岸价格: ( Negotiable ) Get Latest Price
ロケーション: Beijng, China
最低注文量の価格: -
最低注文量: 1 Set
パッケージの詳細: -
納期: 30 days
供給能力: 1000 Set per Year
支払いタイプ: Other, PayPal, D/P, L/C, T/T
製品グループ : Static Volumetric Method