离岸价格
Get Latest Price5000 ~ 7000 USD / Set ( Negotiable )
|1 Set Minimum Order
国:
China
モデル番号:
-
离岸价格:
5000 ~ 7000 USD / Set ( Negotiable )Get Latest Price
ロケーション:
-
最低注文量の価格:
5000 per Set
最低注文量:
1 Set
パッケージの詳細:
Wooden case or according to user's requirements
納期:
within 15 days after we received your advance paym
供給能力:
20 Set per Month
支払いタイプ:
T/T
製品グループ :
-
連絡先担当者 Water
Room 1206, Haiduguoji bulding A, Zhengyang Road, Chengyang District,, Qingdao, Shandong
1. Overview of equipment
Variable frequency constant pressure water supply equipment is a
new type of energy-saving water supply equipment. Variable
frequency constant pressure water supply equipment is using
today's most advanced microcomputer control technology, it is a
electrical integration of high-tech and energy-saving water
supply device which is combined with frequency converter and
motor water pump. Variable frequency constant pressure water
supply equipment uses the output water pressure which is from the
water pump(or users water using flow) as the setting parameters,
through the microcomputer automatic control inverter output
frequency to adjust the speed of water pump motor, to realize the
closed-loop adjustment of users pipe network pressure, at last to
make the water supply system pressure to the given value: the
water consumption increases, the frequency increase, the water
pump speed accelerated; the water consumption decreases, the
frequency is reduced, the pump speed will slow down. By this way
can make sure the user's network has sufficient water pressure at
any time (consistent with the user setting pressure) and water
yield (changes along with the user's water consumption
situation).
With the development of the secondary water supply pressurization
technology, variable frequency constant pressure water supply
equipment has solved these problems fundamentally. According to
data from "water supply equipment promotion center",
Variable frequency constant pressure water supply equipment does
not need to build towers, but has small investment and economic
space occupation, automatic adjustment of water and its pressure,
automatic operation and energy saving, automatic combining with
tap water, there always has water even the electric blackout,
without supervision for years after debugging. Saving *0% of
investment than build towers, *0% of investment than build high
level cistern, greatly save construction investment.
Variable frequency constant pressure water supply equipment is
widely used in enterprises and public institutions, residential
area and the rural production and living. Water supply for
******0 households. Daily water supply is *******0 m3, water
supply height is **0 meters, about *0 layers buildings.
2. Equipment composition
Variable frequency constant pressure water supply equipment is
mainly composed of water pump unit, pressure test buffer tank,
pressure sensors, frequency conversion control cabinet etc., This
equipment can always maintaining the gauge pressure (users pipe
network pressure) is equal to the users setting parameters.
Variable frequency constant pressure water supply equipment can
be used for general life or production. Composition modes
are:
A, frequency conversion water supply equipment connect with
municipal pipeline, then supply water by constant pressure, when
the municipal pipeline water pressure is enough, the water pump
will stop working automatically. Otherwise the water supply
equipment will working and make sure the water pressure is
enough.
B, equipped with small water pump or pneumatic tank, when water
supply pressure is low, automatically shut down the main pump,
and start the small water pump and pneumatic tank, by that way
can save electric when there is small flow and zero flow.
3. Equipment functional characteristics
A, non-negative pressure
Frequency conversion water supply equipment connect with
municipal pipeline directly, increase its water pressure from
municipal pipeline, and will not result in a municipal tap water
pipe network non-negative pressure.
B, Pressure setting
By adjusting the pressure controlling valve, we can set the
municipal tap water pipe network permission water absorption
pressure.
C, Pressure superposed
When exceed licensing suction pressure and flow rate, we can
increase the pressure on the basis of tap water pipe network.
Compared with common reservoir, pressure superposed mode can
reduce pump stations or (and) reduce the rotation speed, then we
can achieve energy saving purpose.
D, Variable-frequency constant-pressure
Equipment is always detecting the outlet water pressure through
pressure sensor, After detection, compare the detection value
with given value, then to determine the number of water pump and
the output frequency from the transducer ( motors and pumps
rotation speed) ,then adjust the water pressure to meet the water
tracking curve.
E, No noise
Considering the environment requirements, we adopt the no noise
professional transducer
F, Blackout without water-break
The equipment will shift it to municipal tap water supplying mode
automatically when there has blackout.
G, Supermatic
The equipment can achieve supermatic control, manual/automatic
shift, main and vice water pump can be changed, pressure
adjustment, constant pressure,high and low voltage protection,
out of phase protection, electric leakage protection, overload
protection, over temperature protection, lack water protection,
leakage detection compensation, tripping protection.
4. Operation theory
According to users requirements, set the feed water pressure
value first, then open the power and begin to run, pressure
sensor monitoring the tap water network pressure, converted
pressure information to electrical signals and send them to the
programmable controller or microcomputer controller, after
analysis and processing, transmit the signals to frequency
converter to control the operation of the water pump, when water
consumption increases, the output voltage and frequency
increases, the RPM of the water pump will increase, then the
output water yield will increase . When there has several sets of
water pump are working, the variable frequency will become to
power frequency, the signal will control the pressure to be
enough. When it is small flow in the night, just the variable
frequency water pump is working, the variable frequency water
pump can protect the pressure.
5. Application
A, new residential quarters, villas, office buildings,
multiple-use building water supplying.
B, high-rise buildings, fire water, senior hotels etc. water
supplying.
C, pressure water supply, the ground tank water-supply system,
etc.
D, many kinds of water cooling and supplying system, hot water
boiler.
E, the middle pressure superposed pump station in water plant,
secondary pressure superposed for tap water .
F, various production of industrial and mining enterprises,
living water, pipe network voltage stability.
G, various types of circulating water, cooling water supplying
system.
H, tap water pressure can not meet the requirement of living and
fire water,then need the pressure superposed.
国: | China |
モデル番号: | - |
离岸价格: | 5000 ~ 7000 / Set ( Negotiable ) Get Latest Price |
ロケーション: | - |
最低注文量の価格: | 5000 per Set |
最低注文量: | 1 Set |
パッケージの詳細: | Wooden case or according to user's requirements |
納期: | within 15 days after we received your advance paym |
供給能力: | 20 Set per Month |
支払いタイプ: | T/T |
製品グループ : | - |