あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。
今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell solar heater controller

Sell solar heater controller

FOB Price

Get Latest Price

100% t/t in advance /

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

50 sets

Packaging Detail:

-

Delivery Time:

one week

Supplying Ability:

-

Payment Type:

-

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. celina

Xinbei, Changzhou, JIangsu

今すぐお問い合わせください

Description

Main technical data: 1. Dimension: **0mm***5mm**8mm 2. Self power consumption: ï&frac*4;œ3W 3. Measuring accuracy of temperature: ±2℃ 4. Temperature range of measurement: 0ï&frac*2;ž**0℃ 5. Maximum power of controlled circulation pump: possible to control 4 pumps, every power ≤**0W 6. Power of auxiliary electrical booster≤***0Wï&frac*4;ˆstandard collocationï&frac*4;‰, ≤***0Wï&frac*4;ˆnot standard,     selection availableï&frac*4;‰ 7. Inputs: 6 inputs, Pt****0 for collector, sensor temperature ≤**0℃ï&frac*4;Œï&frac*4;ˆsilicon cable≤**0℃ï&frac*4;‰   NTC*0K, B=***0for tank, sensor temperature≤**5℃ï&frac*4;Œï&frac*4;ˆPVC cable≤**5℃ï&frac*4;‰ 8. Outputs: 5 outputs, one for electrical booster, 4 for circulation pump (or *-way            electromagnetic valve) 9. Ambient temperature range: ï&frac*4;*0ï&frac*2;ž*0℃ *0. Water protection grade: IP*0. Main functions: 1. 1Clock/week display 2. Chosen system (**8 system available) System1: 1 collector array – 1 storage tank – 1 pump System2: 1 collector array – 2 storage tanks – 2 pumps System3: 1 collector array – 2 storage tanks – 1 pump – 1 electromagnetic valve System4: 2 collector arrays (east/west roof) – 1 storage tank – 2 pumps System5: 2 collector arrays (east/west roof) – 1 storage tank – 1 pump - 1 electromagnetic valve System6: Electromagnetic valve controlled 2 collector arrays (east/west roof) – 2 storage tanks1 pump - 2 electromagnetic valves System7: Electromagnetic valve controlled 2 collector arrays (east/west roof) – 2 storage tanks 2 pumps - 1 electromagnetic valve System8: Pump controlled 2 collector arrays (east/west roof) – 2 storage tanks– 2 pumps - 1   electromagnetic valve 3. Temperature difference on/off 4. Maximum tank temperature (protection of tank at high temperature) 5. Maximum collector temperature (collector cooling function) 6. Collector emergency cut-off 7. Limitation operation of collector at low temperature 8. Frost protection 9. Temperature controlled hot water circulation pump *0. Time controlled hot water circulation pump *1. Temperature controlled auxiliary heating during three time section *2. Holiday function *3. Auto function *4. Auxiliary function[a Temperature difference controlling <â–³T2>, b. High temperature by-pass] *5. Protection functions ( a. Memory protection, b. anti-bacteria protection )

Send a direct inquiry to this supplier

To:

Ms. celina < Changzhou Wuchuang Electronic Co., Ltd >

私は知りたい: