あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。
今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell AD-3530AA Atomic Absorption Spectrophotometer

Sell AD-3530AA Atomic Absorption Spectrophotometer

FOB Price

Get Latest Price

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

-

Minimum Order Quantity:

1

Packaging Detail:

-

Delivery Time:

-

Supplying Ability:

99

Payment Type:

-

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Season

Room 1604,Building 1,No.777,South Hongmei Road,Minhang District, Shanghai, China, Shanghai, Shanghai

今すぐお問い合わせください

Description

element analyzer, ore analyzer, alloy analyzer, portable element analyzer , chemical analysis method AD****0AA Atomic Absorption Spectrophotometer Specifications: Atomic Absorption Spectrophotometer AD****0AA Series is a new generation of domestic high level products that it broke the technology bottleneck of D-lamp background correction. And also provided a reliable safeguard for elements quantitative analysis Character: Unique full reflection optical system D-lamp background correction High resolution and exact peak seeking ability 3 Atomic temperature rise mode Unique design automatic 8 lamps holder system Steady flow full titanium burner Intelligence control function General safety precautions Window***0/XP conciseness, professional, automatic, full operation SP Win-AAS software QA/QC function Full information measurement Main Parameter: Optical System � Instrument Type Single Beam Reflection Achromatic Optics System � Monochrometer: Achromatic C-T � Bandwidth(nm):0.1, 0.2, 0.7, 1.4nm Adjustable � Wavelength Range (nm):******0 � Wavelength Accuracy (nm):±0.*0 � Wavelength Repeatability(nm):�0.*0 � Resolution better than 0.3nm (Mn**9.5nm and **9.8nm peak valley�*0%) Spectrophotometric Properties: � Measurement: ***** � Photometric Range:****5%, *0.**3.*0A � Static Baseline Drift (Cu):±0.**3A/*0min � Dynamic Baseline Drift (Cu):±0.**4A/*0min � Background Correction: D-lamp background correction, Self-absorbance background correction >*0times correction ability (1Abs) � Atomization System: Flame + graphite furnace Flame: � Characteristic Concentration:(Cu)�0.*3ug/mL/1% � Detection limit:(Cu)�0.**6ug/mL � Precision:RSD�1% � Burner:titanium � Nebulizer:hight-efficient glass nebulizer � Spray chamber:anticorrosion material � Safety measures:Flame fuel gas, power assisted gas abnormal pressure protection Graphite Furna

Send a direct inquiry to this supplier

To:

Ms. Season < Shanghai AiCheng Industrial Co. Ltd. >

私は知りたい: