あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。
今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell no baffle-board ultrasonic heat meter

Sell no baffle-board ultrasonic heat meter

FOB Price

Get Latest Price

( Negotiable )

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

-

Minimum Order Quantity:

1000 Set

Packaging Detail:

Export carton

Delivery Time:

20-40 days

Supplying Ability:

50000 Set per Month

Payment Type:

T/T, L/C

今すぐお問い合わせください
無料会員

連絡先担当者 Tony

No.8 Qingdao Middle Road, Weihai, Shandong, China, Weifang, Shandong

今すぐお問い合わせください

Description

ZY-DN*0, ZY-DN*5 no reflection plate ultrasonic heat meter main technique parameters
1. Structure
·Flow sensor: straight through type inwall reflection ultrasonic flow sensor with no reflection plate stand and beam pieces
·Temperature sensor: PT***0 temperature sensor pair
·Optical interface, M-bus interface for data communication
2. Flow
·Rated flow: 1.5~3.5m³/h
·Rated flow and min flow proportion is **0.
3. Temperature and temperature difference
·Temperature measurement range: 4~*5℃
·Temperature difference: 3~*0℃
·Thermal coefficient: Along with inlet and outlet water
4. Connection mode
·Installation position: inlet or outlet as instructed(optional)
·Connection type: threaded connection
·Max working pressure: 1.6MPa
5. Service condition
·Environment condition: Class A
6. Display
·Display: LCD, 8 digits, special symbols
·Dimension: kWh, MJ
·Resolution
(1)Heat: 1kWh or 1MJ
(2)Cumulative flow: 0.*1m³
(3)Temperature: 0.1℃
(4)Temperature difference: 0.1K
7. Data storage
·Data storage: ROM
·Store at least *8 monthsdata
8. Intensity and tightness
·No damage and leakage when the medium temperature is *0℃ less than the max working temperature and the pressure is 1.6 times greater than the max working pressure.
9. Accuracy
·Metering accuracy is Class 2
*0. Pressure loss
·Pressure loss<*0kPa (Industrial standard: Max allowed pressure loss is *5kPa )
*1. Power supply
·Built-in lithium battery(3.6VDC/3.8Ah), external remote data acquisition system power supply is possible
·Battery life: ≥*0 years(Industrial standard: built-in battery life>5*1years )
·Working current: *0~*0μA
*2. Safety requirements
·When the power supply is stoped, the record data of heat, cumulative flow and corresponding time before power off. Can reform normal metering after power is restored 
·The metering characters will not be affected when the magnetic interference strength is not greater than **0KA/m
·The enclosure protection grade is IP*4
·According to relevant national standard, in the environment condition of dry heat, cooling, steady damp-heat, cyclic damp-heat and cryogenic storage, when the analog parameters are input, the heat meter can work normally.
·According to relevant national standard, in the environment condition of line-voltage variation, electrical fast transient, electromagnetic field, electric surge, power frequency magnetic field and electrostatic discharge, the heat meter can work normally.

Send a direct inquiry to this supplier

To:

Tony < Weihai Zhenyu Intelligence >

私は知りたい: