あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。
今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell 808 nm diode laser hair removal machine with sapphire

Sell 808 nm diode laser hair removal machine with sapphire

FOB Price

Get Latest Price

5600 ~ 5800 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

Guangzhou, China

Price for Minimum Order:

Minimum Order Quantity:

1 Piece

Packaging Detail:

Outer packing: Wooden case Inner packing: Thick PE foam

Delivery Time:

5~8 workdays after your payment

Supplying Ability:

200 Piece per Month

Payment Type:

T/T, Western Union

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Chirs

baiyun, Guangzhou, Guangdong

今すぐお問い合わせください

Description

Important  Note

1.Please read this manual carefully before operation.

2.Operator (Doctor) must take professional training of how to operate this machine and relative safety knowledge.

3.Operator and patient must wear protective glasses during treatment.

4.Before treatment , doctor must make sure the patient have no symptoms as following :

  Pregnant , allergic to the intension light , severe scar constitution, drug dependence( such as : heart disease,diabetes,cancer,epilepsy,etc.), having wounds on treatment area, recent received same kind of light treatment( in 6 months) , sunburn ( in 2 weeks)

5. System maintenance, repair must be done by our company professional engineers or authorized engineers .

 

 Safety Note

 

2.1   Protection from Intension Light

 1. Diode laser light wavelength is **8**0 nm ±5 nm .

The light out shot from the window on the head of treatment handle. Please keep the light away from your body, avoid radiation.

2. Please do not see it directly, even wearing the protective glasses or goggle.

3. Flammable, explosive material (such as alcohol, ether, oxygen, etc.),drug which should be easy to break when touch the light , all of this should be kept away from the light radiation zone. 

4. Make sure operator and patient do not wear watches, necklaces and bracelets and other metal jewelry, which can reflect the light.

5. Must supply strict protection to patients' eyes, wearing the protective goggles. 

6. Besides the treatment area, please dont shot the light to other place . No matter you move the handle during treatment or put the handle after treatment, please make sure the light out shot window toward floor or other safe place.

7. Hair on different part of the body have different density, different color, thin or thick, so the absorb ability of light is different, operator need to add the energy step by step according the feeling of patient.
 

2.2 Protection of eyes

1. The output energy of the semiconductor laser light cangreatly damage the vitreous and retinal of eyes.

2. Operator must wear the professional protective glasses. This pair of glasses can protect light whose wavelength from **0nm to ***0nm ,  OD ≥ 4. 

3. Protective glasses just can down the damage of light to eyes, can not completely prevent directly light or reflect light of mirror or glass, or metal surface . So avoid seeing this kind of light.

4. Covered with gauze, wearing protective goggles so that it can better protect patient's eyes.
 

2.3  System operation conditions

1. System output power is ***0W . The input power plug must be the standard single-phase three-pin plugs (international standard plug for power network connection),have ground protection system , should not less than *0A.

2. Before turn on the machine, make sure all the accessories connected well. During working, please don't disconnect any accessories. After operation, turn off the machine, do not allow any person open the shell without permission, for it is very dangerous, Notice the dangerous high pressure inside.  
 

2.4 System safety

1. Water flow sensor : When the laser generator work, it will cause high density of energy. 

Therefore the water cycle cooling system is needed to cooling the laser generator. 

If there are any block or lower speed flow, higher speed flow, the sensor can test it, and give alarm, at the same time, the machine stop work.

2. Water level sensor : If there are not enough water in the water tank, the cooling effect will down. this sensor can test it and give alarm.

3. Water temperature sensor : If the water temperature is over protective temperature level after long time work ,this sensor can test it , and give alarm, at the same time, the machine stop work . 

4. Emergency stop button: when accidents happen, please press this button as soon as possible, avoid accident injury.

5. Handle switch button: under the normal machine condition, all the parts work well, to guarantee the safety, you need to press the handle switch button, so that the laser generator can shot light.

 

 

System features and applications

3.1 Features

1. Treatment handle using sapphire optical crystal as light guide, never worn, life-long use without replacement.

2. Semiconductor refrigeration, air cooling, closed loop force strong temperature water cooling system, make sure long time continuous work. The water flow sensor and water temperature sensor, effect cooling system, greatly increase the life of the machine and the safety factor.

3. Treatment time is short, quick recovery, do not effect patient's normal work.

4. Skin test function: Using adjustable high-powered video camera , can see clear treatment effect before and after treatment, and stored by the file management system. 

 

3.2  Application

Permanent Hair removal of all body part : beard, lips,arm ,leg ,armpit hair,bikini line and so on.Improve pigment ,dark color of the mole ,burgundy birthmarks and other symptoms.

 

System working conditions

1. Temperature of environment : 5~*0°C.

2. Relative Humidity: ≤*0%.

3. Power supply: Single-phase AVC **0V,**0V ± *0% *0A  *0/*0Hz.  Along with the machine main body , there is one input power plug, as the standard single-phase three-pin plugs (international standard plug for power network connection).

4. Treatment room must have a stable and reliable power supply system with ground protection.

5. Adapted voltage range : **0V - **0V  or  **0V***0V

If your local voltage beyond this range , we recommend you add a regulator, and the regulator's power should be greater than 3 KVA. 
 

Send a direct inquiry to this supplier

To:

Ms. Chirs < Jiujiang Shangjia Industry&Trade Co., Ltd >

私は知りたい: