FOB Price
Get Latest Price32000 / Unit ( Negotiable )
|Minimum Order
Place of Origin:
China
Price for Minimum Order:
Minimum Order Quantity:
1 Unit
Packaging Detail:
carton packing
Delivery Time:
7 days
Supplying Ability:
200 Unit per Month
Payment Type:
T/T
連絡先担当者 Mr. Steven
Longding Road, Jiaxing, Zhejiang
Item | Detailed Specification |
Inside dimension | ****0×***0×***0 mm (L×W×H) |
Outside dimension | ****4×***6×***0 mm(L×W×H) |
Pits | 2 rows of pits in the ground for outlet, dimension of each pit is ****0×**0mm (L×W), with galvanized grilles made by twisted steel and flat bar above. |
Front door | Folding door, *-folds, ***0×***0mm (W×H), galvanized steel frame, with polystyrene (EPS) inside, colour: blue. |
Emergency door | 2 units, **0×***0 mm (WXH), colour: white. |
Room body | Profiled bar beams in the roof to strengthen the room body; wall panel thickness:*0mm, width:***0mm, tongue and groove structure, 0.**6mm colour steel with polystyrene(EPS) insulation inside, colour: white. |
Light system | Ceiling Lights: *8Units×4Pcs=*2Pcs×*6W, Side Lights: *2Units×4Pcs=*8Pcs×*6W, up and down interleaving installation, with electronic ballasts. |
Generator cabinet | Intake from side upper, exhaust from back upper, quadrate steel frame, outside is white coated steel, inside is galvanized steel, filled with heat preservation material inside. |
Intake and Exhaust system(2 sets) | Inlet: 2 sets, in total 4×7.5KW double-intake centrifugal fans, model YDW4.5M, air capacity is ****0m3/h for each fan; |
Outlet: 2×*1KW double-intake centrifugal fans, with motor outside, belt-drive, model TAE***0H, air capacity is ****0m3/h for each fan. Equip manual dampers for exhaust. | |
Heating system(2 sets) | 2 units RIELLO RG5S diesel burners, heating productivity: *****0 Kcal/h, stainless steel heat exchanger, pneumatic dampers actuate from spraying to baking cycle |
Purification system | Pre-filter, high efficiency filter(ceiling filter), exhaust fiberglass fiter, activated carbon filter. |
Roof | Galvanized steel. |
Control system | Spraying, heat spraying, baking, time setting, lighting switch, failure indicator, thermostat, power supply switch, emergency stop, ampere meter, voltmeter,hours meter, temperature limit controller, pressure gauge. Exhaust star-delta motor start. |
Total power | *0KW |
Power supply | 1x**0V, 3x**0V, *0HZ. |