あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。 今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell 3-1 Ultrasonic Cavitation Rf Tripolar Slimming Machine Home Use

Sell 3-1 Ultrasonic Cavitation Rf Tripolar Slimming Machine Home Use

FOB Price

Get Latest Price

600 ~ 800 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

Minimum Order Quantity:

1 Piece

Packaging Detail:

export carton

Delivery Time:

3-5 days

Supplying Ability:

2000 Piece per Month

Payment Type:

T/T, Western Union, Money Gram

今すぐお問い合わせください
無料会員

連絡先担当者 Mike

Shenzhen, Guangdong

今すぐお問い合わせください

Description

WORK THEORY

Working principle

*0K Strong sound waves explosion head effectively promote the organization fat metabolism, repel orange peel fat, firming skin,enhancing skin elasticity, etc. And the effect is long lasting. The *0 K sound waves can make a implosion of liquid as the expansion and compression of the wave make the inside of the liquid formed in many small space and what inside this kind of space are gas and steam. During the compression cycle, the *0K sound waves have positive pressure effect on the liquid molecules, while during the expansion cycle the *0K sound waves have positive pressure effect on the liquid molecules. There are cohesion inside of liquid or and biological organization. Inside of the low density fat cells, the cohesiveness of the molecular is weaker.The low negative pressure which is produce by *0 K sound waves will produce organization gap which is called"cavitation phenomenon"inphysics. The implosion of inside and outside of the cells will enhanced the molecular motion and achieve a high energy level, and eventually led to the bursting of the fat cells.

*0K cavitation operation procedure
Click "STRONG SOUND WAVE SYSTEM" enter the operation interface.
1. System default working time is *0 minutes, time range is 0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked time is used to record the total time of the instrument worked. Before working, it will be 0 minute.
3. The system default Intensity is 0.The intensity range is 0~5(standard parameters), press one time to change one unit of standard parameters.
4. The system default output of band is the third one (Continuous band), you can choose the band by click the band mode.
5. Click"START", it starts working and"STOP"for stop working Press"BACK", you can get back to the operation interface.
6. Beautician hold the cavitation explode work head to move slowly on skin, in circle or beeline repeatedly
7. Do not use on back, avoid using on bones.
8. Do not use on uterus part when women do abdomen care. Abdomen treatment during menstruate should be avoided.
9. The machine will pause automatically if the setting time is over. Please click any place of the screen According to the hint.
*0. Clean the leftovers with hot towel, use warm towel to clean the cavitation explode work head.

Caution for using *0K
1.Applied enough gel on skin need treated.
2.Do not stay unmoved on any part of your body ,do not stay on bones.
3.The total treatment time for daily should be within *0 minutes.
4.There will be ultrasonic only when you step on the service brake while using *0K cavitation explode work head.
5.Do not allowed to be placed under the state of no-load to avoid the damage caused by high heat.
6.*0K work head can be used on fresh part of the body, Do not use for facial. If the skin is sensitive or becomes unhealthy, the strength of the power should be adjusted down.

MULTIPOLAR CIRCULATION RF

Skin rejuvenation principle

The circulation medical radio frequency system in 1 seconds will change the electric polarity in electric field millions times of the biological tissue of the therapeutic part , particles of the organization will do Brownian motion(molecular no rules movement) as the same frequency which will make the organization produce columnar distribution of heat, damage collagen hydrogen bonding structure and change the collagen molecules of the three spiral structure, and lead to the immediate collagen sex contraction and as a result of the treatment effect of firming skin;
According to ajusting the energy output, the circulation system makes skin tissues have mild, moderate and severe heat aggression three stages which is similar as the three stages in wound healing (inflammation stage, growth stage, remodeling stage), improve leather remodeling shape, so as to reconstruct the skin and dispel light, medium, heavy wrinkles uteruses Calvin lines and the skin flabby after losingweight. The effect is long lasting.

De-fatting body slimming principle
The medical circulation RF
system will produce columnar distributed hea in the subcutaneous tissue and fully make triglycerides release from the fat cells. Under the action of lipase the triglyceride will cracking into fatty acids and glycerin,then eliminated from the body along with the metabolism. Because of the intelligent system, the medical circulation rf instrument can orientate the fat cells, and release triglycerides quantificationally, thus achieved the localization, the effect of reducing weight rationally and quantificationally.

Multipolar RF system operation
1. System default working time is *0 minutes, time range is 0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked time is used to record the total time of the instrument worked. Before working, it will be 0 minute.
3. The system default Intensity is 0. The intensity range is 0~*0w /cm2,press one time to change one w/cm2.
4. The system default output of band is the third one (Continuous band),you can choose the band by click the band mode.
5. Click"START", it starts working and"STOP"for stop working Press"BACK", you can get back to the operation interface.

Multipolar RF system-face
Click the third module\'MULTIPOLAR RF SYSTEM-FACE"
1. System default working time is *0 minutes, time range is 0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked time is used to record the total time of the instrument worked. Before working, it will be 0 minute.
3. The system default Intensity is 0. The intensity range is 0~*0w /cm2,press one time to change one w/cm2.
4. The system default output of band is the third one (Continuous band),you can choose the band by click the band mode.
5. Click"START", it starts working and"STOP"for stop working Press"BACK", you can get back to the operation interface.


Caution for using RF

1.Beautician should wear insulated gloves during operation.
2.Do not wear any aglet, both for the beautician and the users.
3.The electrode probe must be fully in contact with skin.
4.Do not make the RF electrode stay on any part without moving. Keep it moving on skin slowly.
5.Skin around eyes and forehead is very thin, the RF output intensity should be relatively weakened.
6.Do not contact skin with unipolar when using of bipolar, tripolar,hexpolar RF work head otherwise it will produce pulse discharge, gel paste etc. Products like gel maybe evaporated into a mist.
 

TECHNICAL PARAMETERS

Voltage: **0V/**0V***0V/**0V
Frequency: *0 Hz - *0Hz
Power: =*5W
Output RF: 5MHz
Output supersound: *0KHz
Body materials: PVC plastic

 

ACCESSORIES LIST

1. Mainframe 1
2. Power line 1
3. *0K cavitation explode work head 1
4. Hexpolar RF laser work head for body 1
5. Tripolar RF work head for face 1
6. Accessories bracket 1

Send a direct inquiry to this supplier

To:

Mike < Huntmic Technology Co., LTD >

私は知りたい: