FOB Price
Get Latest Price600 ~ 800 / Piece ( Negotiable )
|Minimum Order
Place of Origin:
China
Price for Minimum Order:
Minimum Order Quantity:
1 Piece
Packaging Detail:
export carton
Delivery Time:
3-5 days
Supplying Ability:
2000 Piece per Month
Payment Type:
T/T, Western Union, Money Gram
連絡先担当者 Mike
Shenzhen, Guangdong
Working principle
*0K Strong sound waves explosion head effectively promote the
organization fat metabolism, repel orange peel fat, firming
skin,enhancing skin elasticity, etc. And the effect is long
lasting. The *0 K sound waves can make a implosion of liquid as the
expansion and compression of the wave make the inside of the liquid
formed in many small space and what inside this kind of space are
gas and steam. During the compression cycle, the *0K sound waves
have positive pressure effect on the liquid molecules, while during
the expansion cycle the *0K sound waves have positive pressure
effect on the liquid molecules. There are cohesion inside of liquid
or and biological organization. Inside of the low density fat
cells, the cohesiveness of the molecular is weaker.The low negative
pressure which is produce by *0 K sound waves will produce
organization gap which is called"cavitation phenomenon"inphysics.
The implosion of inside and outside of the cells will enhanced the
molecular motion and achieve a high energy level, and eventually
led to the bursting of the fat cells.
*0K cavitation operation procedure
Click "STRONG SOUND WAVE SYSTEM" enter the operation interface.
1. System default working time is *0 minutes, time range is
0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked time is
used to record the total time of the instrument worked. Before
working, it will be 0 minute.
3. The system default Intensity is 0.The intensity range is
0~5(standard parameters), press one time to change one unit of
standard parameters.
4. The system default output of band is the third one (Continuous
band), you can choose the band by click the band mode.
5. Click"START", it starts working and"STOP"for stop working
Press"BACK", you can get back to the operation interface.
6. Beautician hold the cavitation explode work head to move slowly
on skin, in circle or beeline repeatedly
7. Do not use on back, avoid using on bones.
8. Do not use on uterus part when women do abdomen care. Abdomen
treatment during menstruate should be avoided.
9. The machine will pause automatically if the setting time is
over. Please click any place of the screen According to the
hint.
*0. Clean the leftovers with hot towel, use warm towel to clean the
cavitation explode work head.
Caution for using *0K
1.Applied enough gel on skin need treated.
2.Do not stay unmoved on any part of your body ,do not stay on
bones.
3.The total treatment time for daily should be within *0
minutes.
4.There will be ultrasonic only when you step on the service brake
while using *0K cavitation explode work head.
5.Do not allowed to be placed under the state of no-load to avoid
the damage caused by high heat.
6.*0K work head can be used on fresh part of the body, Do not use
for facial. If the skin is sensitive or becomes unhealthy, the
strength of the power should be adjusted down.
Skin rejuvenation principle
The circulation medical radio frequency system in 1 seconds will
change the electric polarity in electric field millions times of
the biological tissue of the therapeutic part , particles of the
organization will do Brownian motion(molecular no rules movement)
as the same frequency which will make the organization produce
columnar distribution of heat, damage collagen hydrogen bonding
structure and change the collagen molecules of the three spiral
structure, and lead to the immediate collagen sex contraction and
as a result of the treatment effect of firming skin;
According to ajusting the energy output, the circulation system
makes skin tissues have mild, moderate and severe heat aggression
three stages which is similar as the three stages in wound healing
(inflammation stage, growth stage, remodeling stage), improve
leather remodeling shape, so as to reconstruct the skin and dispel
light, medium, heavy wrinkles uteruses Calvin lines and the skin
flabby after losingweight. The effect is long lasting.
De-fatting body slimming principle
The medical circulation RF
system will produce columnar distributed hea in the subcutaneous
tissue and fully make triglycerides release from the fat cells.
Under the action of lipase the triglyceride will cracking into
fatty acids and glycerin,then eliminated from the body along with
the metabolism. Because of the intelligent system, the medical
circulation rf instrument can orientate the fat cells, and release
triglycerides quantificationally, thus achieved the localization,
the effect of reducing weight rationally and
quantificationally.
Multipolar RF system operation
1. System default working time is *0 minutes, time range is
0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked time is
used to record the total time of the instrument worked. Before
working, it will be 0 minute.
3. The system default Intensity is 0. The intensity range is 0~*0w
/cm2,press one time to change one w/cm2.
4. The system default output of band is the third one (Continuous
band),you can choose the band by click the band mode.
5. Click"START", it starts working and"STOP"for stop working
Press"BACK", you can get back to the operation interface.
Multipolar RF system-face
Click the third module\'MULTIPOLAR RF SYSTEM-FACE"
1. System default working time is *0 minutes, time range is
0:*0~*0:*0 minutes, press one time to change one minute.
2. The system default worked time is 0 minutes, this worked time is
used to record the total time of the instrument worked. Before
working, it will be 0 minute.
3. The system default Intensity is 0. The intensity range is 0~*0w
/cm2,press one time to change one w/cm2.
4. The system default output of band is the third one (Continuous
band),you can choose the band by click the band mode.
5. Click"START", it starts working and"STOP"for stop working
Press"BACK", you can get back to the operation interface.
Caution for using RF
1.Beautician should wear insulated gloves during operation.
2.Do not wear any aglet, both for the beautician and the users.
3.The electrode probe must be fully in contact with skin.
4.Do not make the RF electrode stay on any part without moving.
Keep it moving on skin slowly.
5.Skin around eyes and forehead is very thin, the RF output
intensity should be relatively weakened.
6.Do not contact skin with unipolar when using of bipolar,
tripolar,hexpolar RF work head otherwise it will produce pulse
discharge, gel paste etc. Products like gel maybe evaporated into a
mist.
Â
Voltage: **0V/**0V***0V/**0V
Frequency: *0 Hz - *0Hz
Power: =*5W
Output RF: 5MHz
Output supersound: *0KHz
Body materials: PVC plastic
Â
1. Mainframe 1
2. Power line 1
3. *0K cavitation explode work head 1
4. Hexpolar RF laser work head for body 1
5. Tripolar RF work head for face 1
6. Accessories bracket 1