あなたはまだ TradeKey.com のメンバーではないようです。 今すぐサインアップして、世界中で700万を超える輸入業者および輸出業者と接続します。 今すぐ加入、無料 |
BOOK A CALL
Book Call On Your Favorite Time
Code
🗘

By Signing Up. I agree to TradeKey.com Terms of Use, Privacy Policy, IPR and receive emails related to our services

Contact Us
Sell Sell Online pH meter for Aquarium, water tester, PH tester

Sell Sell Online pH meter for Aquarium, water tester, PH tester

FOB Price

Get Latest Price

40 ~ 50 / Piece ( Negotiable )

|

Minimum Order

Place of Origin:

China

Price for Minimum Order:

Minimum Order Quantity:

10 Piece

Packaging Detail:

1pc in box, 20pcs in carton

Delivery Time:

30days

Supplying Ability:

1000 Piece per Week

Payment Type:

T/T, Western Union, PayPal

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Enya

Mingfa commercial center, Xiamen, Fujian

今すぐお問い合わせください

Description

pH***1 pH meter aquarium online

Product Specifications
Range : pH: 0.*0 ~ *4.*0pH
Temperature : **0 ℃ ~ *0 ℃ (**8 ℉ ~ **8 ℉)
Resolution : pH: 0.*1pH
Temperature : 0.1 ℃ (0.2 ℉)
Accuracy : pH ± 0.1pH
Temperature ± 1.0 ℃ (± 2.0 ℉)
Power supply : DC 6V ( can be equipped with power adapter )
Automatic shutdown : 6 minutes
Temperature Compensation : 0 ℃ ~ *0 ℃
Operating temperature : 0 ℃ ~ *0 ℃
Size : *5mm × *5mm × *8mm
Weight: *0 g

Procedure
1 Remove the electrode protective cover, will PH electrode into the electrode \'s BNC connector socket .
2 Rinse the electrode with distilled water and dry with filter paper attached to the electrodes of the water.
3 Touch the " " switch boot, tap "℃ / ℉" key to switch to Fahrenheit Celsius .
4 pH meter electrode into the test solution and gently stir until the numerical stability , read the display ( NOTE: The display on the row for the pH value , the lower the temperature value ) .
5 After use, clean the electrode , touch " " switch off , put the electrode protective sleeve.

pH calibration
1 . The pH electrode into a pH of 6.*6 ( the temperature at *5 ℃) standard mixed phosphate buffer solution, gently shake the electrode .
(2) with a small screwdriver to adjust the potentiometer until the display value and the standard buffer solution at ambient temperature pH values.
3 . The pH electrode immersed in pH4.*1 phosphorus or potassium hydrogen phthalate standard pH9.*8 borax buffer solution , gently shake the electrode .
4 shows the pH value of the buffer value is compared to the error should be within the allowable range .

Precautions
In the following cases , the instrument must be recalibrated .
After calibration has been used ( or place ) for a long time
Frequent use of special electrodes
Accuracy requirements are relatively high .

Battery Installation
If the backlight brightness decreased, measurement error is larger or appear blurred , replace the battery. When replacing the battery , pull out the battery to replace the small cover sheet , note the battery polarity. For long-term monitoring , connect the power adapter.

Warranty
The instrument from the factory on the date one year warranty, guarantee the production and material defects caused . But if the insurance period, the instrument needs repair or replacement , and the cause of the damage , not the user\'s carelessness or improper use , please send us the equipment and instructions agent or our company, we have to be maintenance free .
Ë™ digital display with backlight
Ë™ 6 minutes automatic shutdown
Ë™ Online Monitoring

Send a direct inquiry to this supplier

To:

Ms. Enya < E&E TECH LIMITED >

私は知りたい: