The oil industry, chemical
industry,Electric power.
Energy and Water treatment system.
Industrial process control
Performance
parameters
Reference temperature:*5℃
Pressure range *0.1~*0MPa
Pressure type Gage pressueã€absolute pressure
Output signal 0~5Vã€0~*0Vã€1~5Vã€4~*0mAã€0~*0mA
Accuracy(%FS) 0.1 0.*5 0.5
Nonlinearity(%FS) ≤0.2
Hysteresis(%FS) ≤0.2
Repeatability(%FS) ≤0.2
Zero drift(%FS/℃) ≤0.1
Full scale drift (%FS) ≤0.*2
Stability (%FS/Year) ≤0.*5
Operating voltage(V) *2~*6V DC(Standard:*4V)
Operating temperature(℃) **0~*5℃
Overload capacity(%) >**0
Life span more than 9 million times pressure cycle
Load resistance (Ω) ≤**0
Response time(ms) ≤1
Media Media compatible with **6L
Diaphragm material **6L or The ceramic diaphragm
Housing material SUS**4 or **6L
Pressure interface Fast clamp
Enclosure rating IP*5
Weight *0g