Automatic Large Screen CT PT Analyzer

Automatic Large Screen CT PT Analyzer

FOB Price

Get Latest Price

1 ~ 2 / Set

|

Minimum Order

Place of Origin:

-

Price for Minimum Order:

Minimum Order Quantity:

1 Set

Packaging Detail:

485mm*356mm*183mm, 13kg

Delivery Time:

10 days

Supplying Ability:

10000 Set per Month

Payment Type:

T/T, L/C, Western Union, Other

今すぐお問い合わせください
無料会員

連絡先担当者 Ms. Tina

9-10 Nanping, Nanan, Chongqing, Chongqing

今すぐお問い合わせください

Description

Tests for current transformer:
Excitation curve and parameters test
Turns ratio test
Ratio and phase error test
Polarity mark check
Coil resistance measurement
Secondary loop burden measurement
Error line curve test for protection CT
Transient CT parameters test
CT nameplate guess
Saturation hysteresis loop curve measurement
Tests for voltage transformer:
Turns ratio test
Polarity test
Secondary burden test
Coil resistance test
Applications for CT PT Tester:
CT nameplate check
CT parameters check in work burden
CT transient parameters analysis
CT ratio and phase error calibration
PT routine test
Specifications:
Test standards: IEC******1, IEC******6, GB***8, GB****7, C*7.*3
Power supply: AC**0V±*0%,*0Hz/*0Hz±*0%
Power output: 0.1~**5V (AC)
Current output: 0.**1~5A(RMS)
Power output:**0VA
Maximum knee voltage measurement:*5kv
Current measurement:
Range:0~*0A (automatically change range in 0.1/0.4/2/*0A) 
Error <±0.1%*0.*1%FS</span>
Voltage measurement:
Range:0~**0 V (automatically change range in 1V/*0V/*0V/**0V)
Error < ±0.1%*0.*1%FS</span>
Turns ratio measurement:
Range :1~****0,
1~***0 error<0.*5%</span>
***0~***0 error>0.1%
***0~****0 error<0.2%</span>
Phase measurement: error:±2min,resolution:0.*1min
Coil resistance measurement:
Range:0~8kΩ (automatically change range in 2ohm/*0ohm/*0ohm/**0ohm/8kohm)
Error< 0.2%RDG*0.*2%FS</span>
Maximum resolution:0.1mΩ
Temperature measurement:**0~**0 Celsius degree, error<3 Celsius degree</span>
CT Secondary burden:
Range 0~**0ohm (automatically change range in 2ohm/*0ohm/*0ohm/**0ohm)
Error <0.2%RDG*0.*2%FS</span>
Maximum resolution 0.**1ohm
PT Secondary burden:
Range 0~*0kohm (automatically change range in **0ohm/8kohm/*0kohm)
Error <0.2%RDG*0.*2%FS</span>
Maximum resolution: 0.1ohm
PT ratio measurement:
Range :1~****0,
1~***0 error<0.2%</span>
***0~****0 error<0.5%</span>
Saved data groups:>***0groups
Work condition: Temperature:**0°C~*0°C, moist:<</span>*0%
Size: **5mm***6mm***3mm
Weight: <*5Kg</span>