Slip resistance test | right angle coupler |
When load value
is 7KN,displacement of flat tube cross should less than
7mm; when load value is *0KN,displacement of coupler cover plate on standing tube should be less than 0.5mm |
|
swivel coupler |
hen load value
is 7KN,displacement of flat tube cross should less than
7mm; when load value is *0KN,displacement of coupler cover plate on standing tube should be less than 0.5mm |
||
damage resistance test | right angle coupler | When load is *5KN, each part of coupler should not be damaged | |
swivel coupler | When load is *7KN, each part of coupler should not be damaged | ||
torsional rigidity test | right angle coupler | When torsional moment is **0Nm, displacement should be less than *0mm | |
tension test | sleeve coupler | When load is 4KN, displacement should be less than 2mm | |
compression test | base-plate coupler | When load is *0KN, each part of coupler should not be damaged | |
tension test of bell shape cap |
1.Loading from 0KN to
*5KN and then release completely 2.after release completely, loading from 0KN to *0KN and keep at *0KN for 2min, each part of coupler should not be damaged |
||
strength of bowl shape socket |
1.loading from 0KN to
*0KN and then release completely 2.after release completely, loading from 0KN to *0KN and keep at *0KN for 2min, each part of coupler should not be damaged |
||
strength of flat tube cross joint |
1.loading from 0KN to
*5KN and then release completely 2.after release completely, loading from 0KN to *0KN and keep at *0KN for 2min, each part of coupler should not be damaged |
||
weld strength of flat tube cross joint |
1.loading from 0KN to
*0KN and then release completely 2.after release completely, loading from 0KN to *5KN and keep at *5KN for 2min, each part of coupler should not be damaged |
||
compress test of jack support |
1.loading from 0KN to
*0KN and then release completely 2.after release completely, loading from 0KN to **0KN and keep at **0KN for 2min, each part of coupler should not be damaged |
||