FOB Price
Get Latest Price55000 ~ 75000 / Set
|Minimum Order
Place of Origin:
-
Price for Minimum Order:
Minimum Order Quantity:
1 Set
Packaging Detail:
wooden box
Delivery Time:
30 days
Supplying Ability:
10 Set per Month
Payment Type:
T/T
連絡先担当者 Mr. Danny
7F, Building C, Jingu Pioneer Park, Longzhu 4th Road, Shenzhen, Guangdong
MobileSparkler Specification and features |
|||
High-volt Generator BWG**0 |
Maximum power | *0kW | |
Norminal power | *2kW | ||
Kvp range | *****0kV | ||
Current range | *****0mA | ||
Current time product | 0.****0mAs | ||
Inverter frequency | *0kHz | ||
X-ray
Tube Toshiba E***3X |
Focal spot | 0.6mm/1.2mm | |
Maximum input power | *0kW/*6kW | ||
Maximum input current | **0mA/**0mA | ||
Anode type | Rotating anode | ||
Anode thermal capacity | **0kHU | ||
Anode rotational speed | ***0r/min | ||
Target angle | *2° | ||
Collimator | Inherent filtration | 1.2 mm Al /*0kV | |
Rotation degree | ±*0° |
Detector I Varian ***6R(wired) |
X-ray sensitive area | *2.4cm×*5.3cm | |
Pixel size | **9μm | ||
DQE | *0%±5%(0 lp/mm, RQA5) | ||
Pixel matrix | ***2×***6 | ||
Limiting resolution | 3.6 lp/mm | ||
Cycle time | *0s | ||
A/D conversion | *4bit | ||
Image preview | ≤6s | ||
Detector Thales ***3EZ(wireless) |
X-ray sensitive area | *3cm×*5cm | |
Pixel size | **8μm | ||
DQE | *6%(0 lp/mm, RQA5) | ||
Pixel matrix | ***0×***0 | ||
Limiting resolution | 3.4 lp/mm | ||
Cycle time | *0s | ||
A/D conversion | *6bit | ||
Image preview | ≤3s | ||
Detector Thales ***0EZ (Mini panel, wireless) |
X-ray sensitive area | *0cm×*4cm | |
Pixel size | **8μm | ||
DQE | *0%±5%(0 lp/mm, RQA5) | ||
Pixel matrix | ***0×***0 | ||
Limiting resolution | 3.4 lp/mm | ||
Cycle time | *0s | ||
A/D conversion | *6bit | ||
Image preview | ≤1s | ||
Detector Iray ***7P(wired) |
X-ray sensitive area | *2cm×*5cm | |
Pixel size | **0μm | ||
DQE | |||
Pixel matrix | ***0×***0 | ||
Limiting resolution | 3.3 lp/mm | ||
Cycle time | 9s | ||
A/D conversion | *4bit | ||
Image preview | ≤7s | ||
Detector Iray ***7V(wireless) |
X-ray sensitive area | *2cm×*5cm | |
Pixel size | **0μm | ||
DQE | |||
Pixel matrix | ***0×***0 | ||
Limiting resolution | 3.4 lp/mm | ||
Cycle time | 9s | ||
A/D conversion | *4bit | ||
Image preview | ≤7s | ||
Detector PerkinElmer Xrpad ***6MED(wireless) |
X-ray sensitive area | *3.0cm×*5.5cm | |
Pixel size | **0μm | ||
DQE | *5%(0 lp/mm, RQA5) | ||
Pixel matrix | ***0×***6 | ||
Limiting resolution | 5.0 lp/mm | ||
Cycle time | 9s | ||
A/D conversion | *6bit | ||
Image preview | ≤6s | ||
Position and physical specification | Tube vertical rotation angle | ±**0° | |
Tube tilting angle | **0°~*0° | ||
SID | *****0cm | ||
Tube transverse motion | *****4cm | ||
Cantilever type | cross telescopic arm | ||
Column rotation angle | ±**0° | ||
Climbing capacity | 7°(Automatic) | ||
Dimension | **7cm×*7cm×**4cm | ||
Weight | **0kg | ||
Features | Motor driven | Yes | |
Exposure by battery power supply | Yes | ||
Remote control exposure | Yes | ||
Anti-collision braking | Yes | ||
Image workstation | Monitor | *9 inch touch screen, ***0×***4 | |
Processer | Core I3 dual core processer | ||
RAM | ≥4GB | ||
SATA | ≥**0GB | ||
Operating System | windows 7 | ||
Operating software | DROC | ||
Software function | Patient registration and data edit | Yes | |
Expose parameter adjustion | Yes | ||
image view | Yes | ||
image process and output | Yes | ||
Data mannagement | Yes | ||
DICOM 3.0 | Yes |