Features | ||||||||||||||||||||
â— Constant voltage output with multi interface or with sensor | â— Typical lifetime ≥ 50000 hours | |||||||||||||||||||
◠Plastic case with interface ,Class II. | ◠100% full load bur-in test | |||||||||||||||||||
â— Built-in EMI filter with tiny ripple,flicker-free | â— Protection: Short circuit/Over current/Over voltage/Over load | |||||||||||||||||||
â— High performace and reliability | â— 3 years warranty | |||||||||||||||||||
|
|
|||||||||||||||||||
Specifications | CE RoHS SELV | |||||||||||||||||||
Model# | Rated Power | Input Voltage | Output Voltage | Output Current | Efficiency | PF | IP | Dimension | Weight | Warranty | ||||||||||
NC-12024-LV4 | 24W | 200-240Vac | 12Vdc | 2A | 85% | >0.5 | IP20 | 118*52*18mm | 80g | 3 years | ||||||||||
NC-12036-LV4 | 36W | 200-240Vac | 12Vdc | 3A | 86% | 138*52*18mm | 100g | |||||||||||||
NC-12060-LV4 | 60W | 200-240Vac | 12Vdc | 5A | 88% | 168*60*20mm | 150g | |||||||||||||
NC-12100-LV4 | 100W | 200-240Vac | 12Vdc | 6A | 88% | 198*60*20mm | 200g | |||||||||||||
  | ||||||||||||||||||||
Characteristics | Frequency | 50/60Hz |   |   |   |   |   |   | ||||||||||||
Voltage tolerance | ±5% |   |   |   |   |   |   | |||||||||||||
Load regulation | <2% |   |   |   |   |   |   | |||||||||||||
Leakage current((mA ) | < 0.5mA / 230VAC |   |   |   |   |   | ||||||||||||||
Ripple&noise | < 650mVP-P |   |   |   |   |   |   | |||||||||||||
hold-up/start-up time time | 100ms, 30ms,20ms/ 230VAC |   |   |   |   | |||||||||||||||
Leakage current((mA ) | < 0.5mA / 230VAC |   |   |   |   |   | ||||||||||||||
Protection | Over current | above 108%-116%,power limiting, recovers automatically after fault removed |   | |||||||||||||||||
Over voltage | switch off, recovers automatically after fault removed |   |   | |||||||||||||||||
Short circuit | hiccup mode,recovers automatically after fault removed |   |   | |||||||||||||||||
Environment | Operating Temperature | -25℃~~+45℃ |   |   |   |   |   | |||||||||||||
Storage Temperature | -30℃~~+80℃ |   |   |   |   |   | ||||||||||||||
Humidity | 20~~95% |   |   |   |   |   |   | |||||||||||||
Security | LVD | 2014/35/EU,EN61347-1:2015,EN61347-2-13:2014 |   |   | ||||||||||||||||
EMC | 2014/30/EU,EN55015:2013+A1:2015, EN61547:2009,EN61000-3-2,EN61000-3-3:2013 | |||||||||||||||||||
Voltage Insulation/Isolation Resistance | I/P-O/P:3.75KVAC,I/P-O/P:>100M Ohms/500VDC/28℃/65% RH |   |   | |||||||||||||||||
Classification of Installation and Use | Class II |   |   |   |   |   |   | |||||||||||||
Note | ◊ All parameters NOT specially mentioned are measured at 240VAC input, max rated load and 25℃ of ambient temperature | |||||||||||||||||||
◊ Ripple & Noise are measured at 20MHz of bandwidth by using a 300mm twisted pair-wire terminated with a 0.1uF & 47 uF parallel capacitor. | ||||||||||||||||||||
◊ The driver is considered as a component to be operated in combination with equipment,since performance will be affected by the complete installation. | ||||||||||||||||||||
◊ Good heat dissipation will prolong the working life of the driver.Please ensure good ventilation. | ||||||||||||||||||||
◊ Please check if the output voltage of any LED lights used comply with the working voltage of the product. | ||||||||||||||||||||
◊ Be ware of high power pressure may caused by short circut when installing metal casing products. | ||||||||||||||||||||
◊ Please ensure all wires connections and polarities are correct before appling power to avoid any damages to LED Lights. | ||||||||||||||||||||
◊ The product shall be installed and serviced by a qualified person. | ||||||||||||||||||||
◊ Please
contact supplier if a fault occurs. |