Multiple working process——TPDã€TPRã€TPOã€TPSR, pulse
titration, pretreatment and BET specific surface area
Multipath independent air source——besides the carrier gas and
reaction gas, each path controlled independently and mixed at
certain ratio
Multiple gas port——three for carrier gas and the other three for
reaction gas
Steam Generator – It is equipped with a saturated steam generator
and convenient to use reaction gas like liquid NH3.
Can be connected to GC or MS – It can be connected to the gas
chromatography (GC) or mass spectroscopy (MS).
Auxiliary Detector – The instrument can output a voltage signal
which is convenient to connect gas auxiliary detector, such as
FID.
Material Structure - Stainless steel piping, seal for fluorine
rubber, application in special environment requires to be
customized from the company.
Flow Control – Using mass flow controller (MFC) software control,
the flow is adjustable between *0 to **0sccm and software
controls gas coefficient. High Temperature Furnace – The highest
temperature is ***0℃, and the stove heating rate can be
adjustable from 1℃/min to *0℃/min.
Air Refrigeration – Open (shell type) furnace can be quickly
cooling and optional refrigerator achieving rapid refrigeration.
Optional Cryotrap – The temperature can be rising from ***0℃.
Temperature Control – Piping, steam generator. Stove and TCD
temperature all can be controlled by digit
Thermal Conductivity Cell Detector – *-arm rhenium tungsten TCD
has extremely high linear, accuracy, sensitivity and stability.
Very small dead volume - Small volume valve and 3 mm pipe can
reduce dead volume, thus reduce the deviation of the peak.
Sample Support – U type pipe of large size can be convenient for
sample loading and cleaning, and can add powder, rod or shot
sample.
Sample Loading – Sample tube took down freely is convenient to
load samples.
Heating Pipeline – All the pipeline, valve and liquid carburetor
are heated to prevent condensation.
Safety – Independent furnace temperature thermal protection,
sealing pressure reducing valve, current circuit breaker, fuse,
the system design has timely security protection.
Software Features
The FINESORB****0 is controlled by powerful Windows R–based
operating software. It provides all the convenient features you
are accustomed to when using Windows-based programs.
Point-and-click operations, pull-down menus, access to multiple
printers and network drives, multitasking capability, and much
more featured in the FINESORB****0 user interface.
Additionally, familiar Windows format reduces the time required
for training new operators, which improve the efficiency more.
The principle diagram of each process visually displays on the
screen, so the status of each valve can be intuitively known.
The process of dynamic test shows the state of each valve.
Show the value of each detector and sensor and display digital
quantity or curve according to the needs.
Display the setting parameter value in programming time,
convenient to compare with the measured value.
Visually display the state of each device, normal operation or
alarm state.
The carrier gas and reaction gas in the process of test, and
whether to use steam generator can all be controlled by
software program.
Purging time in test process can be controlled by program.
The temperature of the stove can be heated in maximum *0
sections of program and can automatically save programming
state. The control module has the function of automatic
correction and learning with precision 0.*2℃.
The temperature of TCD thermal conductivity cell can be
programmed control, according to the need to set thermostatic
temperature, and can always maintain high precision constant
temperature with precision 0.*2℃.
The constant-current source by numerical control can be
programmed output, and can keep high precision constant-current
with precision 0.1%.
The temperature of steam generator also can be programmed
control, choose appropriate temperature according to the
evaporation temperature of liquid.
The temperature of condensation-preventing system in pipeline
and gas path also can be programmed control, make the equipment
be in normal use in bad environmental conditions.
lIn the process of test, the software can record
and display some important parameters. Sampling data will
automatically treat after the test.
It is able to process the
measured data into report and mark manually
The data can be imported to EXCEL or ORIGIN.
Choosing mode for printing report
Technique Parameter
TPR Temperature programmed reduction
TPD Temperature programmed desorption
TPSR Temperature programmed surface reaction
TPO Temperature programmed oxidation
Pulse Chemisorptions
BET specific surface area
Noble metal dispersion detection
Detection Precision
Minimum recognizable volume: *0*4cm³/g
Accuracy: ±1%
Reproducibility: ±1%
High Temperature Furnace
Room temperature ranges to ***0°ï¼ˆtemporary use above
***0°ï¼‰
Heating ratio ***0℃ /min,not only the fast heating
control but also the slow heating
Shell type which can dissipate heat open, cool to the room
temperature within in *0 min with fan
Gas Circuit Port
Three paths of carrier gas (He, Ar, etc)
Three paths of reaction gas (H2, CO, CO2, O2, NH3, etc)
Three paths (analysis gas exit, carrier gas exit and reaction
gas exit)
Flow Control
Two MFC control the flow, the range is: ****0ml/min
Setting MFC parameter of different gas via the software, also
for mixture
TCD
TCD, specially treated detector with safety device and
secondary enlarging system
Detector close to the reactor, has very small dead volume
Vapor Generator
Equipped with thermocouple and soft heating jacket, it can
vaporize the liquid carbinol, Ethanol and pyridine, etc
Dewar Flask and Cold Trap Tube
Low temperature liquid can be kept in the Dewar flask (like
liquid nitrogen or mixture of liquid nitrogen and
isopropanol
Cold trap tube can cool the liquid products of TPR and TPSR
Reactor
U quartz tube, OD 8mm,ID 6mm, maximum ***0°
Internal thermocouple for temperature, measurement point is
on the catalyst surface
Pipeline
3mm stainless iron pipeline, **6 stainless iron material,
and smooth treatment for the inner wall of the pipe
Solenoid Valve
Solenoid valve controls the pipeline switch and selections,
service life over 1 million
Selecting different valve body, spool and sealed material
according to different air,
Sealing
Selecting fluororubber Perfluor rubber and graphite
according to different application environment
Thermal Conductivity Cell Thermostatic
Thermal conductivity cell temperature controlled, precision
is 0.2%FS
Lower cell temperature can be used on the condition of
inorganicgas, therefore improve the TCD
precision
Thermal Conductivity Constant Current Source
High precise Thermal conductivity constant current source,
0.1 current accuracy, temperature entrainment 5ppm/min.
Electrical Pulse Injection
Electrical controlled pulse injection reduce the labor
strength
Easy change of the injection volume
Strong Corrosion Air Explaining
Supporting NH3,
sulfide, NOx, Organic gas liquid