製品仕様

  • Basic feature:Single or multiple component isothermal adsorption

タイトルまたは説明

Technique parameter
Basic feature
Single or multiple component isothermal adsorption and desorption
Temperature: room temperature~ **0℃
Operation pressure: *0MPa
System maximum pressure: *0MPa
Sample Cylinder, Reference Cylinder
 
Sample Particle Size
≤*0um
Sample Weight
**0g
Reference Cylinder Volume
**0ml
Reference Cylinder Quantities
6pcs OD: *0mm Length: **0mm
Sampler Cylinder Volume
**0ml
Material
Stainless Steel
Pressure Seal
Specified Metal Ring Seal
Stressor
Gas Booster Pump
Pressure Device
 
Thermostat
 
Oil Bath pan
*0L*2pcs
Oil Bath pan Size
*0cm(length)**8cm(width)**4cm(depth)
Temperature Setting
Independent Zones
Oil Bath pan Circulation
Internal Installation
Constant Temperature Oil
BYOD
Pressure Acquisition
 
Pressure Sensor
Three Wire Pressure Sensor
Pressure Range
 ***0MPa
Rated Pressure
*0MPa
One-piece Barometer
Precision±0.1%
Quantity
*2pcs
Output
 3mv/v
Temperature Acquisition
 
Temperature Detection System
Temperature Sensor±0.1℃
Multi-channel Digital Converter Precision
*6
Gas source
 
Aggregate Supply
3
Gas Input
Methane,Helium,Carbon Dioxide
Pressure
*0MPa
Stability
3%
Electric Gas Regulator
 
Aggregate Supply
3
Pressure
*0MPa
Stability
1%
Input
 ***0v
Booster Pressure
 0.6Mpa
Computer Control
 
Computer
Basic Frequency0.3GHZ,
Internal Storage1GB, Hard Disk **0GB
Auto Control
Computer
System Software
 
Other accessories (additional)
Sample cylinder: 1
Manual needle valve: 3
Pneumatic valve: 2
RTD: 2
Headers: 6
High pressure gas cylinder: different gas for 3 each
Stainless iron pipe: 4
Stable pressure power: 1
Sealed circle: 4
 
Isothermal Adsorption Process
Industrial analysis implements complied with GB/T******1
Air Tightness Inspection
Air inflation
Filling Helium to system, pressure is higher than the highest pressure 1MPa of Isothermal Adsorption Experiment. System temperature adjusted to the reservoir temperature. Continuous observation for the system seal condition, if it’s good, to the next experiment.
Free Space Volume Measurement
Temperature
System temperature is adjusted to reservoir temperature
Inflation
Open the cylinder; inflate the gas to system, adjust standard pressure valve, and then close the standard room valve
Data Acquisition
Open the valve of standard room and sample cylinder collect the data after the balance of pressure, do the volume experiment twice, allowable error is ±0.1cm3, calculate the coal volume and get the blank
Isothermal Adsorption Experiment
Experiment Pressure determination
The highest experimental pressure is set up to 1.2 times of reservoir pressure, minimum pressure is 8MPa
FINESORB-ISO Data Acquisition Software
FINESORB-ISO Absorb/Desorb Data Processing Software
Multicomponent Gas Absorb/Desorb Data Processing softer ware
Chinese specification provided


 
Air Compressor
 
 
Inflation
Open regulated valve and standard room valve, inflate methane to system, and adjust the standard room pressure to ideal pressure.
Data acquisition
After get the ideal pressure and stable temperature, start the data collection of the isothermal adsorption experiment program
Time of Adsorption Balance Determination
No less than *2 hours at least
Repeating Step 3 *5, until the end of experiment of last pressure spot
 
Data Processing
The calculation of coal sample volume and free space volume
The design formulas of coal volume as follows:
 
  
VS- Coal sample volume, units of measurement (cm3);
P*- Balanced pressure, units of measurement (MPa);
P*- Initial pressure of reference cylinder, units of measurement (MPa);
P*- Initial pressure of sample cylinder, units of measurement (MPa);
T*- Balanced temperature, units of measurement (K);
T*- Initial temperature of reference cylinder, units of measurement (K);
T*- Initial temperature of sample cylinder units of measurement (K);
V*- System total volume units of measurement (cm3);
V*- Reference cylinder volume units of measurement (cm3);
V*- Sample cylinder volume units of measurement (cm3);
Z*- Gas compression factor under the balance condition, dimensionless
Z*- Initial gas compression factor of reference cylinder, dimensionless
Z*- Initial gas compression factor of sample cylinder, dimensionless
 
After getting the coal sample volume, calculate the free space volume of sample cylinder. Free Space Volume refers to the sum of various volumes that coal particle space after the coal sample put into the sample cylinder, micro-flow gap of internal coal particle size, the remaining free space of sample cylinder, and connection tube and internal space volume. Calculation formulas of free space volume as follows:
Vf- Free space volume, unit of measurement (cm3)
V*- Total volume of sample cylinder, unit of measurement (cm3);
Vs- Coal sample volume, unit of measurement (cm3);
Z*- sample cylinder initial gas compressed factor, dimensionless
 
Calculation the absorption capacity of each pressure spot
According to balance pressure and temperature of reference cylinder and sample cylinder, calculate adsorption capacity of different pressure spot Formulas as follows
                           
PV=nZRT
 
P-Gas pressure, unit of measurement (MPa)
V- Gas volume, unit of measurement (cm3);
n- Gas mole number, unit of measurement (mol)
Z- Gas compressor factor, dimensionless
R- Molar gas constant, unit of measurement (U·mol*1·K*1)
T- Thermodynamic temperature unit of measurement (K)
 
Respectively obtain the gas mole number of inner sample cylinder before pressure spot balance and after balance, the gas mole number of sample cylinder (N2), mole number of coal sample adsorption of gas (ni)
Ni=n*-n2
 
ni- Gas mole number, unit of measurement (mol)
N*- Sample cylinder‘s gas mole quantity after balance, unit of measurement (mol).
N*- Sample cylinder‘s gas mole quantity after balance,, unit of measurement (mol).
Adsorption gas volume of each pressure spot
VI=ni * *2.4 * ***0
 
The gas volume of each pressure spot adsorption:
 
V adsorption=V i/ c
V-adsorption- Adsorption capacity, unit of measurement (cm3/g)
-total volume of adsorption gas, unit of measurement (cm3/g)
-coal sample weight, unit of measurement (g)
Data Calculation and Report
Adsorption Isotherm
According to adsorption capacity of each balance pressure V and pressure F drew the adsorption isotherm.
Experiment Precision
5.1 Repeatability
VL repeatability of relative error less than *5%
PL repeatability of relative error less than *5%
5.2 Reproducibility
VL reproducibility of relative error less than *0%
PL reproducibility of relative error less than *0%
5.3 Sample experimental weight
Related coefficient R of P/V and P is greater than 0.*8
Sample experimental quality
P/V and its relative coefficient R >0.*8
 
 

国: China
モデル番号: FINESORB-3120
离岸价格: Get Latest Price
ロケーション: Quzhou zhejiang
最低注文量の価格: -
最低注文量: 1 Piece
パッケージの詳細: Steamed smoked wooden cases
納期: after receive TT 15days
供給能力: 10 Piece per Month
支払いタイプ: T/T
製品グループ : Analyzer

Send a direct inquiry to this supplier

To:

Anna < zhejiang Finetec Instruments Co., Ltd >

私は知りたい: