离岸价格
Get Latest Price|
1 Piece Minimum Order
国:
China
モデル番号:
YL-6TA
离岸价格:
ロケーション:
China
最低注文量の価格:
-
最低注文量:
1 Piece
パッケージの詳細:
1pcs/box
納期:
1~3 days
供給能力:
1000 Piece per Week
支払いタイプ:
T/T, L/C
製品グループ :
連絡先担当者 Mr. Shiwei
2nd Floor No. 11, Dongxiao Road, Shantou, Guangdong
1series
|
YL*6TA(*6mmX*6mmX*0mm) YL*6TB(*8mmX*6mmX*0mm)
YL*6TD(*2mmX*2mmX*0mm) YL*6TE(*8mmX*8mmX*0mm)
|
2. Setting
accuracy
|
± 0.5% FS± 1 during the
whole measure range.
|
3. Measure
precision
|
± 0.2% FS±
1
|
4. Sample
frequency
|
2
times/sec.
|
5.The s(standard
signals
|
K
|
6. The ways of control
temperature
|
(1) Intelligent setting:
factory Initial setting P, I, D.
But when the temperature is
fluctuating around the critical point, the value of P, I and D can
be adjusted.
(2) Upper-lower limit
controlling: modify P=0, and set "HY"(the *9th item in the third
level of menu) as what you need to control the section, and set
"Fr" as "0".
|
7. Output
control(selectable)
|
” I” for
Impulse output ***0mA and ***0m;
"U" for
Voltage output **5 VDC and **5VDC;
YL*6TAI /
YL*6TAU ( *6 X *6 X *0mm)
YL*6TBI / YL*6TBU (*8 X *6 X
*0mm)
YL*6TDI / YL*6TDU (*2 X *2 X
*0mm)
YL*6TEI / YL*6TEU (*8 X *8 X
*0mm)
“S” for
Impulse voltage *2VDC.
“R" for Relay controlling AC contactor(standard voltage AC*2V) YL*6TAS / YL*6TAR ( *6 X *6 X
*0mm)
YL*6TBS / YL*6TBR (*8 X *6 X
*0mm)
YL*6TDS / YL*6TDR (*2 X *2 X
*0mm)
YL*6TES / YL*6TER (*8 X *8 X
*0mm)
|
8.Time-delay
function
|
"second", "minute" time
range can be chosen:****9s and ****9m
|
9.Time-start
function
|
Time-delay automatic
control or manual control. After the temperature reaches the set
point, time-delay function will start to work automatically, while
manual time-delay can activated by external
.
|
*0. Relay contact
load
|
**0VAC/3A (resistive),
**0VAC/1A (conductive, CosΦ =0.4)
|
*1. Impulse voltage
load
|
*2VDC, max=*0mA(impulse
SSR, with protection of short circuit)
|
*2.Analog voltage and
current load
|
(Standard) **5VDC,
***0mA, loading resitance Max=**0Ω.
|
*3. Alarm
funtion
|
4 kinds of alarm of
deviation value for upper and lower limit, the absolute value of
alarming funtion for upper and lower limit is free to
combine
|
*4.Alarming output
load
|
relay contact **0VAC/3A
(resistive), **0VAC/1A (conductive, CosΦ =0.4)
|
*5.The waste of
voltage
|
*****0VAC, ****0Hz, ≤
5W
|
*6.Insulating
resistance
|
≥ *0MΩ (testing
condition is **0VDC), (the main output is current or non-connected
voltage, the resitance of its (or output)terminal and CT
terminal don' t need to be tested
|
国: | China |
モデル番号: | YL-6TA |
离岸价格: | Get Latest Price |
ロケーション: | China |
最低注文量の価格: | - |
最低注文量: | 1 Piece |
パッケージの詳細: | 1pcs/box |
納期: | 1~3 days |
供給能力: | 1000 Piece per Week |
支払いタイプ: | T/T, L/C |
製品グループ : | Timing Relay Temperature controller |